1 Instruction manual
IMPORTANT!
READ CAREFULLY BEFORE USE!
KEEP FOR FUTURE REFERENCE!
2 Description
The TK Adapter V2 connects the SKS BUS to a telephone system. Per telephone system at least one TK Adapter is
needed. All telephones communicating with the TK Adapter must be suitable for DTMF. The TK Adapter needs an ana-
logue connection with the telephone system. Using the TK Adapter it is possible to connect up to 15 bell buttons with a
telephone system.
The TK Adapter manages for example forwarding to telephones capable of DTMF, switching off ringtones or redirection
to a main number (master). These functions can be activated generally for all attendees or for single attendees only. The
configuration can easily be carried out via the program interface of the TK Adapter V2 Software, Alternatively it can also
be done with limited functions using a telephone suitable for DTMF.
2.1
Contractual use
3
Forwarding door calls as well as internal calls to a telephone suitable for DTMF in a telephone system
3
Setting up to two call numbers per attendee
3
Switching on and off of automatic door opener
3
Redirecting some or all attendees to a main number (master)
3
Use only indoors in places free from dripping or spraying water
2.2
Features
3
The TK Adapter V2 functions as a connection between the SKS BUS and a telephone system.
3
With the TK Adapter V2 it is possible to connect up to 15 bell buttons to a telephone system.
3
All telephones communicating with the TK Adapter V2 need to be suitable for DTMF
3
The TK Adapter V2 needs an analogue port at the telephone system.
3
Forwarding after a certain time span (linked calls), time adjustable
3
Two call numbers of up to 24 digits can be configured for each attendee
3
Redirecting calls during a configurable time span
3
Can be configured with your personal computer and (limited) via telephone
3
Is needed once per telephone system
3
USB cable enclosed
3
Working temperature from: -5 °C to +45 °C
3
Protection type IP20
2.3
Scope of delivery
3
TK Adapter V2
3
USB cable (type A-B)
3
USB stick with an installer for the PC configuration software in Windows (requires NET-Framework 4.5)
3
Ten-pole terminal board
3
Installations instructions