3.3.5 Thermal Overload
When the motor is overheated because of excessive current draw or prolonged use in hot weather, a
thermal overload switch will cut power to the motor windings. Determine the cause of overheating and
make necessary corrections. Allow the motor to cool approximately 20 minutes. During this time, the
thermal overload switch will automatically reset.
3.4 HOIST OPERATION
The electric hoist is activated by movement of the directional switch in the desired direction of travel.
Travel may be stopped by releasing the directional switch, which cuts power to the motor and sets the
hoist brake.
WARNING: Allow Hoist to come to a full stop before changing direction of travel. Rapidly
changing position of directional switch may result in loss of control.
3.5 HOIST INSTALLATION AND REEVING
These mounting and reeving instructions are directed to the reeving of a hoist mounted on the stirrup of
a stage. These same instructions are generally applicable to the reeving of Compact CX 500 Hoist
mounted on work cages, bosun chairs and other work platforms.
Read and understand the paragraphs describing operation of the hoist before attempting reeving. Prior
to reeving, test the Sky Lock in accordance with Pre-reeving Inspection, Section 5.4.2.1; and inspect the
Hoist in accord with Section 5.6. Figure 3.5 illustrates a typical assembly with safety equipment.
Figure 3.5
STEP 1:
Rigging
Install rigging as described in Section 7.0, or arrange for rigging to be installed by your local Sky
Climber Office.