1.6.3 Air Powered Hoists
1.6.3.1 Before using air powered hoists, check the pressure setting of the pressure regulator. The
pressure setting should be equal to the working pressure indicated on the air motor data plate.
1.6.3.2 Use only approved connector plugs and air hoses with strain relief, correctly assembled from
hoist to air distribution yoke.
1.6.3.3 Use an air hose off sufficient cross-section.
1.6.3.4 Use air hoses that are in good condition.
1.6.3.5 In case the permissible noise level of 79dB is exceeded ear protection is necessary.
1.7 CONTROLS
1.7.1
Before switching on the main power: check all hoist controls and verify that they are in the
“neutral” or “off” position.
1.7.2
Before moving the platform: verify that all the persons on or close to the platform are standing
clear and are aware you are going to raise or lower the platform before moving.
1.7.3
Before raising or lowering the platform: check that the controls are operating as indicated on
the control panel. Activating the “UP” button / lever has to initiate the upward movement. If this
is not the case: call for a service mechanic.
WARNING: Always wait for the hoist to come to a complete stop before changing direction
of movement, otherwise this may result in loss of control.
1.7.4
Activate the control buttons / levers only by manual action. It is not allowed to block the
control push buttons by any other means.
1.8
OPERATOR’S SUPPORT/WORK PLATFORM
1.8.1
Check stirrup bolts daily and verify that the bolts are still in position and tightened firmly.
1.8.2
Never operate a suspended work cage or platform without having the guard-rails, toe boards,
bumpers, lifelines, lanyards and safety harnesses in position.
1.8.3
When operating the platform: keep it as level as possible. If necessary: operate one hoist in
order to re-establish the level position.
1.8.4
When suspended: do not climb or stand on : guard-rails, toe boards, platform supported objects.
Do not reach over the ends or sides of the platform. Do not use ladders or scaffolding that are
put on the platform deck for reaching out to higher levels.
1.8.5
The Bosun chair shall only carry the operator. It is not allowed to suspend or mount any other
items on or from the chair.
1.8.6
Do not attempt to bridge from one platform to another, nor to any other structure or other
equipment. Embarking/disembarking of the platform is only allowed at ground or top level.
1.8.7
Do not attempt to transfer a work platform to another
“drop” while suspended. Only transfer the
platform from one suspension location to another when it is lowered and standing on a level and
solid surface.
1.8.8
In order to prevent damage to the aluminum structure every contact with caustic materials, acids
fluids and fumes is strictly prohibited. Select wooden or fiberglass-made platforms for working
in a caustic environment.