KY CLIMBER
11
®
Safe Working Load
1. Determine working load limit (WLL) of hoist.
2. Add WLLs of hoists used.
3. Compare total WLL of hoists less the selfweight of
platform with load rating (LR) of platform.
4. Use lowest value as the Safe Working Load (SWL).
Do not concentrate all loads but equally distribute over total
length of platform.
If loads are concentrated on one half of a platform then the
SWL equals the WLL of 1 hoist less half the self-weight of the
platform (never exceed floor rating).
The load on the floor panels must not exceed the floor rating:
maximum 180kg per meter platform or 120lbs per foot platform.
Standard Configurations & Load Ratings per EN1808
Platform
Configurations Suspension Self-weight Load Rating
Length
Distance
kg
lbs
kg
lbs
2m
2
6 9
113
249
360
795
3m
3
9 9
129
285
540
1190
4m
2+2
13 6
164
363
720
1585
5m
2+3
16 6
181
399
900
1985
6m
3+3
19 6
197
435
1080
2380
7m
2+3+2
23 3
232
512
1080
2380
8m
3+2+3
26 3
249
548
1080
2380
9m
3+3+3
29 3
265
584
1080
2380
10m
2+3+3+2
33 0
300
662
920
2028
11m
2+3+3+3
36 0
316
698
750
1650
12m
3+3+3+3
39 0
333
734
680
1500
Configurations for stages with End Stirrups (two point suspension systems) per EN1808.
END STIRRUP CONFIGURATIONS
SKY STAGE ULTRA®
EE36002
ED 2018.08.03
Note: Platform sections may not be used in configurations and lengths other than those shown in these tables. Contact Sky Climber®
Engineering to discuss any variations.
SUSPENDED DISTANCE
CANTILEVER
CANTILEVER
5 - 6m
6 - 7m
7 - 8m
8 - 9m
COMING SOON
9 - 12m
12 - 15m
Suspended
Distance
0 - 1m
1 - 1,5m
1,5 - 2m
2 - 3m
Total Stage Cantilever
Total Stage Cantilever
Total Stage Cantilever
Total Stage
Cantilever
Rating(lbs)
Rating(lbs)
Rating(lbs) Rating(lbs)
Rating(lbs) Rating(lbs)
Rating(lbs)
Rating(lbs)
Cantilever
Note: Connecting frame is never to be placed outside intermediate stirrup.
Cantilever distance is the distance from the suspension point to the end of the stage, not the distance from a part of the
intermediate stirrup to the end of stage
Conformance to
the rated load
capacities & configurations
as shown in these tables is
critical to the safe use of
Sky Stage Ultra. Use of
other configurations or
greater weights could result
in serious injury.
Connecting frame is never to be placed outside intermediate stirrup