KY CLIMBER
9
®
Note: Connecting frame is never to be placed outside intermediate stirrup.
Cantilever distance is the distance from the suspension point to the end of the stage, not the distance from a part of the
intermediate stirrup to the end of stage
END STIRRUP CONFIGURATIONS
SKY STAGE ULTRA®
EE36002
ED 2018.08.03
5 - 6m
2000
500
-
-
-
-
-
-
6 - 7m
1500
500
-
-
-
-
-
-
7 - 8m
1500
500
1500
500
-
-
-
-
8 - 9m
1000
500
1000
500
-
-
1000
250
9 - 12m
1000
500
1000
500
1000
500
1000
250
12 - 15m
750
500
750
500
750
500
750
250
Suspended
Distance
Cantilever
Total Stage Cantilever
Total Stage Cantilever
Total Stage Cantilever
Total Stage
Cantilever
Rating(lbs)
Rating(lbs)
Rating(lbs) Rating(lbs)
Rating(lbs) Rating(lbs)
Rating(lbs)
Rating(lbs)
0 - 1m
1 - 1,5m
1,5 - 2m
2 - 3m
Safe Working Load
1. Determine working load limit (WLL) of hoist.
2. Add WLLs of hoists used.
3. Compare total WLL of hoists less the selfweight of
platform with load rating (LR) of platform.
4. Use lowest value as the Safe Working Load (SWL).
Do not concentrate all loads but equally distribute over total
length of platform.
If loads are concentrated on one half of a platform then the
SWL equals the WLL of 1 hoist less half the self-weight of the
platform (never exceed floor rating).
The load on the floor panels must not exceed the floor rating:
maximum 180kg per meter platform or 120lbs per foot platform.
Configurations for stages with End Stirrups (two point suspension systems) per UL1322.
Platform
Configurations Suspension Self-weight Load Rating
Length
Distance
kg
lbs
kg
lbs
2m
2
6 9
113
249
900
2000
3m
3
9 9
129
285
900
2000
4m
2+2
13 6
164
363
900
2000
5m
2+3
16 6
181
399
900
2000
6m
3+3
19 6
197
435
900
2000
7m
2+3+2
23 3
232
512
680
1500
8m
3+2+3
26 3
249
548
680
1500
9m
3+3+3
29 3
265
584
450
1000
10m
2+3+3+2
33 0
300
662
450
1000
11m
2+3+3+3
36 0
316
698
450
1000
12m
3+3+3+3
39 0
333
734
450
1000
13m
2+3+3+3+2
42 9
368
811
340
750
14m
3+2+3+3+3
45 9
384
847
340
750
15m
3+3+3+3+3
48 9
401
883
340
750
Standard Configurations & Load Ratings per UL
Note: Platform sections may not be used in configurations and lengths other than those shown in these tables. Contact Sky Climber®
Engineering to discuss any variations.
Conformance to
the rated load
capacities & configurations
as shown in these tables is
critical to the safe use of
Sky Stage Ultra. Use of
other configurations or
greater weights could result
in serious injury.
SUSPENDED DISTANCE
CANTILEVER
CANTILEVER
Note: Connecting frame is never to be placed outside intermediate stirrup