Notes:

 

1.  The correct direction should be followed to insert the microSD 

card into the slot.  

2.

 

A new microSD card should be formatted before using. You can 
format the microSD card through the Motor+ software.  

 

5.2   Turning on/off Argo 

The Argo will automatically turn on and start Normal Looping 
Recording after the ignition.  

5.3   Video Recording and Photo Taking 
Normal Looping Recording  

The Argo will start Normal Looping Recording once turned on. The 
Red status LED lights up during Normal Looping recording. Video 
recording is repeatedly creating successive files of 3 min, 5 min or 10 
min. The most outdated file will be replaced if the memory is full for 
continuous recording. 
 

 

Event Protection Recording  

Files will be protected from the auto deletion if an impact is detected. 
The sensitivity of impact detection can be adjusted through the 
Motor+ software.  

By pressing 

during normal recording can also enter the Event 

Protection Recording mode to protect your  video files. The Purple 
status LED lights up during Event Protection recording. 
 You can store up to 30 Event protection videos to the Argo. 
Each Protected video file length will be 20 sec. 
 

Photo Taking 

Press 

 once during recording for taking a photo.  The Status LED 

will flash each time a photo is taken. You can store up to 500 photos 
to the Argo. 
 

6.  Connecting the Argo via Wi-Fi 

6.1 Enabling the Wi-Fi Function 

1. 

Connect the Argo to an external power supply with the included 
DC in to USB cable. The Wi-Fi mode will turn on automatically. 

2. 

The Green Wi-Fi LED lights up to indicate the Wi-Fi is warming 
up.  

3. 

Wait for Wi-Fi to initialize. The Wi-Fi LED will flash when the Wi-
Fi is active or connected.  

4. 

To turn off Wi-Fi, press and hold 

 or disconnect Argo from 

the external power supply. 

 

6.2 Connecting the Argo to your Computer or 

Smart Device 

1. 

Turn on the Wi-Fi mode on Argo. 

2. 

Go to network setting on your computer or Smart Device to 
enable the Wi-Fi setting. Search for the “MOTORPLUS” network. 

3. 

Enter password 

“123456789”

 to connect to the Argo. 

6.3 Using the Free App 

1. 

Search for Motor+ app via the Google Play Store or  App Store. 

2. 

Download and install the app to your smart device. 

3. 

Connect the Argo to  your Smart Device by  following the steps  in 
section 6.2. 

4. 

Open your Motor+ app.  You may conduct relevant operations in 
accordance  with specific Application interface. 

 

7  Connecting the Argo to a Computer 

You may also connect the Argo to  your computer and view videos 
and pictures on the computer monitor.  
1. 

Connect the Argo to  your computer with a USB cable to enter 
into USB mode. 

2. 

Your computer will recognize the  Argo as a “Removable Disk”. 
The Blue Status LED will light up. Open the disk and go to 
relevant file folder to view, import, copy,  transfer or delete the 
videos or photos.  

 

 
 

Note : 

If the Removable Device Window did not launch automatically, go to 
your “My Computer” and find the device under Removable Disk. 
 

8  Specifications 

 

Lens 

125

 o 

 Wide Angle Lens 

Still Image Resolution 

on Recording 

3MP on 1296p 
2MP on 1080p 
1MP on 720p

 

Video Resolution 

1296P: 2304x1296 P30 
1080P: 1920x1080 P30 
720P: 1280x720 P30 

Video Format 

MPEG4 (H.264) .MOV File 

Photo Format 

JPG 

GPS Sensor 

Yes 

G Sensor 

Yes 

Wi-Fi 

Yes 

USB Port 

Micro USB 

Power 

DC in 

Microphone 

Yes 

Speaker 

Yes 

Language 

English 

Voice Language 

English, Mandarin 

Wi-Fi 

Yes 

Battery 

185mAh 

Operation Temperature -20 to 60 degree 

Storage Temperature

 

-40 to 80 degree 

Dimension (L x W x H)  63X43X21 mm 

Weight 

66.3g 

 
9  Computer System Minimum 

Requirements 

 

Operating System 

Windows 7&8 / Vista /  XP and  Mac OS 10.5 
or above 

CPU 

Pentium 

 or above4 / 3.0G or faster 

recommended 

RAM 

At least 256MB    

Interface 

USB port 

CD 

4x speed CD ROM or above  

 
10 Troubleshooting  

 

Problem 

Cause 

Solution 

Cannot turn on the 
Argo 

Low battery 
power 

Connect the Argo with 
power source by DC or 
USB cable 

Cannot find 
removable disk 
after connecting 
the Argo to the 
computer 

Connection 
failure 

1. Make sure all cable 

connections 
are secured 

2.Restart the computer if 

necessary 

Blurry images 

1. The Argo has 

not been 
installed 
steadily 

2. The lens of 

Argo is dirty 

1. Reinstall the Argo 
2. Clean the lens with 

soft and dry cloth 

 
      

FCC Statement 

Warning:  Changes or modifications to this unit not expressly approved 

by the party responsible for compliance could void the user’s authority to 

operate the equipment. 

 
NOTE:  This equipment has been tested and found to comply w ith the 
limits for a Class B digital device, pursuant to Part 15 of the FCC 
Rules.  These limits are designed to provide reasonable protection 
against harmful interference in a residential installation.  This equipment 
generates, uses and can radiate radio frequency energy and, if not 
installed and used in accordance w ith the instructions, may cause 
harmful interference to radio communications. 
 
How ever, there is no guarantee that interference w ill not occur in a 
particular installation.  If this equipment does cause harmful interference 
to radio or television reception, w hich can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the follow ing measures: 

• Reorient or relocate the receiving antenna. 

• Increase the separation betw een the equipment and receiver. 

• Connect the equipment into an outlet on a circuit different from that to 

w hich the receiver is connected. 

• Consult the dealer or an experienced radio/ TV technician for help. 

This device complies w ith Part 15 of the FCC Rules. Operation is subject 

to the   follow ing tw o conditions: 

 (1) This device may not cause harmful interference, and 

 (2) This device must accept any interference received, including 

interference that may cause undesired operation. 

 

Shielded cables must be used w ith this unit to ensure compliance w ith 
the Class B FCC limits. 

 

 

                                                                                                                 

      

 

AM-MPC03G-GB-STD-3 

 

 

 

 

Reviews: