SkyeModule Nova Datasheet
-
Preliminary
Page
|
38
Skyetek Inc
1732 Wazee St. Ste 202
Denver, CO 80202
www.skyetek.com
Main 720.328.3425 Fax:720.228.2400
Parameter address: 0x0001
Length (bytes): 4
Default value: 0xXXXXXXXX (depending on release)
The firmware version uses this format:
o
Major revision (1 Byte)
o
Minor revision (1 Byte)
o
Current build number (2 bytes)
Read-only
13.3.3
Hardware Version
Returns the current hardware version of the reader
Parameter address: 0x0002
Length (bytes): 4
Default value: 0xXXXXXXXX (depending on release)
The hardware version uses the following format:
o
Major revision (1 Byte)
o
Minor revision (1 Byte)
o
Current build number (2 bytes)
Read-only
13.3.4
Product Code
Returns the SkyeTek product code identifier. (Each SkyeTek Product has a unique product code.)
Parameter address: 0x0003
Length (bytes): 2
Default value: 0x0010
Read-only
13.3.5
Reader ID
This was used for a deprecated SkyeTek protocol feature. It is now used as the I
2
C address of the reader
in I
2
C mode. The least significant 7 bits of the reader ID act as the 7-bit I
2
C address.
Example: A value of 0x0000001B would indicate an I
2
C address of 0x1B
Parameter address: 0x0004
Length (bytes): 4
Default value: 0xFFFFFFFF
Read/write
13.3.6
Reader Name
Identifies a reader with a 32-byte user-defined name.