SKYJACK, Page 112
SJRT Compact Series
Engine Powered
DIAGNOSTIC / OUTPUTS MENU OPTIONS
LAMP/P2-7
Displays state of outrigger control box light
STABLE/P2-8
Displays state of stable (all legs touching the ground) output
TILT/P2-9
Displays state of tilt
LRe/P4-1
Displays state of left rear outrigger extend valve
RRe/P4-2
Displays state of right rear outrigger extend valve
RFe/P4-3
Displays state of right front outrigger extend valve
LFe/P4-4
Displays state of left front outrigger extend valve
LRr/P4-5
Displays state of left rear outrigger retract valve
RRr/P4-6
Displays state of right rear outrigger retract valve
RFr/P4-7
Displays state of right front outrigger retract valve
LFr/P4-8
Displays state of left front outrigger retract valve
P4-9 MON
Displays the voltage to the outrigger valve (can only be seen when operating in
auto-level or retract)
DIAGNOSTIC / LOG MENU OPTIONS
MAX.BATTERY
Displays maximum recorded battery supply voltage
OCM1
version
Displays part number and software version of
GP106
EZcal
version
Displays software version of
EZcal
ACCESS LEVEL MENU OPTIONS
CODE xxxx
“ACCESS LEVEL” 3 (allows viewing only)
“ACCESS LEVEL” 2 (allows setup on OCM1)
ADJUSTMENTS MENU OPTIONS (factory set - not adjustable)
Xtilt TRIP
Displays the tilt trip point in the “X” orientation
Ytilt TRIP
Displays the tilt trip point in the “Y” orientation
TILT ENTRY
Displays the tilt delay time
TILT EXIT
Displays the tilt delay time
Xlevel TRIP
Displays the tilt trip point in the “X” orientation during the auto-level function
Ylevel TRIP
Displays the tilt trip point in the “Y” orientation which applies during the
auto-level function
MACHINE SETUP MENU OPTIONS (factory set - not adjustable)
DEFAULTS
Allows all adjustments & machine settings to be set to defaults
WARNING: all
GP106
settings will be changed; use with caution!
CALIBRATE LEVEL
Allows levelling of the integral tilt sensor of the
GP106
, when the vehicle is
positioned on level ground (see Appendix Four)
TILT MODE
Allows configuration of the
GP106
tilt output (P2-9):
1 – output turns on to light lamp when tilted
2 – output turns off to cutout functions when tilted
3 – output turns off to cutout functions when tilted AND elevated
TILT FILTER
Displays the filter applied to the tilt measurements during the auto-level function
(used to minimize the effect of vehicle vibrations on the tilt measurement)
Xlevel TARGET
Displays the tilt in the “X” orientation at which the auto-level function will complete.
Ylevel TARGET
Displays the tilt in the “Y” orientation at which the auto-level function will complete.
tilt SLACK
Displays the amount of vehicle tilt exceeding the Xtilt TARGET and/or Ytilt TARGET in
which the auto-level function will not attempt to level
EXAMPLE
:
Xtilt TARGET=0.3°, Ytilt TARGET=0.7°, tilt SLACK=0.5°
If machine is tilted to 1.0° in the X and Y orientations, the auto-level function will attempt
to level the X orientation (0.3+0.5<1.0) but will not attempt to level the Y orientation
(0.7+0.5>1.0), RANGE: 0.0° to 1.0°, default 0.3°
Go
to
Discount-Equipment.com
to
order
your
parts