SKYJACK, Page 113
SJRT Compact Series
Engine Powered
IMPORTANT
Each phase must be completed before the next phase can be carried out.
All phases must be completed before the aerial platform can be operated.
Always follow the instructions of the Calibration instrument.
1.
Ensure the aerial platform is parked on a firm, level surface.
2.
Elevate the scissors high enough to lay a level across the base tubes. Ensure there is no debris on the base
and the level sits flat. Do not elevate the machine higher than the high speed/tilt override limit switch.
3.
Manually operate the outriggers and level the machine in 4 places: left side, right side, front and rear. All 4
outriggers must be firmly placed and all 4 tires are off the ground.
4.
Double check that the machine is level at all 4 points.
5.
Connect the
EZcal
tool to the P1 connector on the CONTROL MODULE.
6.
The display will show
“
Help: Press Enter
”.
By using Left/Right buttons, select the “Access Level (3 )” from the menu and press the
ENTER
button.
7.
The display will show
“
Access Level: Code (0000)
”.
By using the Up/Down buttons, enter the Access Level Code (1 1 2 2) followed by pressing the ENTER
button.
8.
The display will show
“
Access Level 2
”.
By using Left/Right buttons, select the
“
Setups
”
from the menu and press the
ENTER
button.
9.
The display will show
“
Setups: Change Defaults
”.
Select the
“
Change Defaults
”
from the menu and press the
ENTER
button.
10.
The display will show
“
Defaults, 0 = Custom
”.
By using Up/Down buttons, select the
“
Defaults:
Code
Setting for your Model
(For
Default
Code Refer
to Table 5-3)
”
from the menu and press the
ENTER
button and followed by
ESCAPE
button.
11.
The display will show
“
Setups Change Defaults
”.
By using Left/Right buttons, select the “
Calibrate Level
” from the menu and press the
ENTER
.
12.
The display will show
“
Calibrate Level: Yes: Enter, No: ESC
”.
Select the
“
Yes
”
from the menu by press the
ENTER
button.
13.
The display will show
“
Calibrate Level: Tilt 0.0’ , 0.0
’”.
Select the
“
ESCAPE
”
from the menu once.
14.
The display will show
“
Setups Calibrate Level
”.
Select the
“
ESCAPE
”
from the menu once again.
15. The Calibration procedure is complete, unplug and remove the EZ-Cal.
16. Close the hydraulic/electric cabinet.