127
SJ6826RT, SJ6832RT
213560ABA
Hydraulic Systems
Section 4 – Troubleshooting Information
4.3-18 Load Sense System Codes
1. Flash Code F01: Check HWFS
-
This message is given if the GP102 startup tests have not
completed.
Check HELP message for more information.
2. Flash Code F02: Not Ground Mode -
This message is given if the machine is not in ground mode,
P2-2 must be high.
Calibration can only be carried out in ground mode.
3. Flash Code F03: Not Stopped -
This message is given if the machine is not in ground mode,
P2-2 must be high.
Check DIAGNOSTICS / SWITCHES to see which function
switch is closed.
4. Flash Code F04: Tilted -
This message is given if the machine is tilted.
Calibration must be carried out with the machine level.
If the machine is level, use the
5. Flash Code F05: Bad Height -
This message is given if the height sensor output P4-3 is out
of range at the start of calibration.
The height sensor output must be between 1.0V and 4.0V.
Check DIAGNOSTICS / SENSORS to see the output.
A reading of 0V or 5V is probably due to a wiring
problem.
6. Flash Code F06: Check Elev -
This message is given if the elevation switch P2-10 is open at
the start of calibration, when the operator has confirmed the
PLATFORM DOWN? question.
If the platform is down, check the elevation switch wiring.
7. Flash Code F08: Check Elev -
This message is given if the elevation switch P2-10 is closed
at the end of the DYNAMIC lift, when the platform should be
fully raised.
This message would occur if the UP switch was
accidentally opened near the start of the DYNAMIC lift.
If the platform is fully raised, check the elevation switch
wiring.
8. Flash Code F09: Bad Height -
This message is given if the height sensor output P4-3 is out
of range at the start of the DYNAMIC lift.
The height sensor output must be between 1.0V and 4.0V.
Check DIAGNOSTICS / SENSORS to see the output.
9. Flash Code F10: Bad Height -
This message is given if the height sensor output P4-3 is out
of range at the end of the DYNAMIC lift.
The height sensor output must be between 1.0V and 4.0V.
Check DIAGNOSTICS / SENSORS to see the output.
A reading of 0 V or 5 V is probably due to a wiring
problem.
10. Flash Code F11: Not Up -
This message occurs at the start of the DYNAMIC lift if the
operator selects a function other than UP.
Select the UP function.