47
SJ6826RT, SJ6832RT
213560ABA
Electrical Parts List
Section 3 – System Component Identification and Schematics
3.5 Electrical Parts List
CONTROL (B+)
NORMALLY
CLOSED
CONTACT
SUPPLY (B+) (Common)
GROUND (B-)
NORMALLY
OPEN
CONTACT
Index
No.
Skyjack
Part No.
Qty.
Description
8CCR
127035
1
ENABLE RELAY
9CR2
127131
1
RELAY, 12 Volt (Outrigger enable)
9CR3
127131
1
RELAY, 12 Volt (Outrigger enable proof)
10BCR
127035
1
RELAY, 12 Volt (40 Amp) (main power)
10CR1
127035
1
RELAY, 12 Volt (40 Amp)
10CR2
127035
1
RELAY, 12 Volt (40 Amp)
15CR
127035
1
RELAY, 12 Volt (40 Amp) (Reverse drive)
16CR
127035
1
RELAY, 12 Volt (40 Amp) (Forward drive)
17CR
127035
1
RELAY, 12 Volt (40 Amp) (Small pump)
17DCR
127131
1
RELAY, 12 Volt (Outrigger lift disable)
19CR
127035
1
RELAY, 12 Volt (40 Amp) (Large pump)
20CR
127035
1
RELAY, 12 Volt (40 Amp) (Series/Parallel drive)
20ACR1
127035
1
RELAY, 12 Volt (40 Amp) (Series/Parallel)
20ACR2
127035
1
RELAY, 12 Volt (40 Amp) (Series/Parallel)
28ACR1
127035
1
RELAY, 12 Volt (40 Amp) (Small pump dump enable)
28ACR2
127035
1
RELAY, 12 Volt (40 Amp) (Large pump dump enable)
31CR
127035
1
RELAY, 12 Volt (40 Amp) (Glow plug)
32ACR
127035
1
CONTACTOR, Engine start
32CR1
127035
1
RELAY, 12 Volt (40 Amp)
32CR2
127035
1
RELAY, 12 Volt (40 Amp) (Engine start)