DC Electric Full-size RTs
December 2007
Page 31
TM
Section 2 - Operation
Function Tests
2.9 Function Tests
Function tests are designed to discover any malfunctions
before aerial platform is put into service. The operator
must understand and follow step-by-step instructions
to test all aerial platform functions.
impORTANT
Never use a malfunctioning aerial
platform. If malfunctions are discovered,
aerial platform must be tagged and
placed out of service. Repairs to aerial
platform may only be made by a qualified
service technician.
After repairs are completed, operator must perform a
pre-operation inspection and a series of function tests
again before putting aerial platform into service.
Prior to performing function tests, be sure to read and
understand
2.9-1 Test Battery Connectors
1. In battery roll-out tray, disconnect battery
connectors.
Result: Aerial platform functions should not
operate.
2.9-2 Base Control Console
wARNiNG
Ensure that you maintain three points of
contact when using the ladder to mount/
dismount platform.
1. Use the ladder of aerial platform to access
platform.
2. Close the gate.
3. On platform control console, pull out “
”
emergency stop button.
4. Insert key into base/off/platform key switch
and select “
” base position.
5. Use the ladder to dismount from platform.
6. On base control console, select “
” base
position.
7. On battery roll-out tray, ensure battery
connectors are properly connected.
Battery Connectors
Emergency Stop Button
Base/Platform
Switch
Raise/Lower
Switch