47
SJ30 AJE SJ30 ARJE
213213AAA
Function Tests
Section 4 – Pre-operation
4.3-2 Base control console
NOTE
While operating the emergency power unit, the
base controls will override the platform controls,
even when the emergency stop button on the
platform is depressed.
1.
On platform control console, pull out emergency
stop button.
WARNING
Ensure that you maintain three points of contact to
mount/dismount platform.
4.3-3 Testing base emergency stop light
and base emergency stop button
1.
Turn base/off/platform key switch to base
position.
2.
On base control console, pull out emergency
stop button.
▪
Result:
Emergency stop light should
continuously illuminate.
3.
Push in emergency stop button and attempt to
raise or lower the platform.
▪
Result:
Platform raising and lowering functions
should not operate.
4.
Pull out emergency stop button.
4.3-4 Testing function enable switch and
all boom functions
WARNING
Ensure that there are no personnel or obstructions
in test area and there is sufficient room for boom
to swing.
1.
Do not hold function enable switch. Attempt to
activate each boom and platform switch.
▪
Result:
All boom and platform functions
should not operate.
2.
Hold function enable switch and activate each
boom and platform function.
▪
Result:
All boom and platform functions
should operate as selected.
TM
Base/off/platform key
switch
Emergency
stop
Emergency power
switch
Function enable
switch
To
order
go
to
Discount-Equipment.com