50
SJ30 AJE SJ30 ARJE
213213AAA
Section 4 – Pre-operation
Function Tests
4.3-8 Platform control console
WARNING
Ensure that you maintain three points of contact to
mount/dismount platform.
1.
Ensure both emergency stop buttons are pulled
out.
2.
Turn the base/off/platform key switch to the
platform position.
3.
Enter platform and close gate (if equipped).
WARNING
DO NOT operate any control on platform control
console without proper fall protection secured to
designated location in platform. Failure to avoid
this hazard could result in death or serious injury!
WARNING
Ensure that there are no personnel or obstructions
in test area and that there is sufficient room for
boom to swing.
4.3-9 Testing secondary guarding
electrical (SGE)
1.
Press the sensor bar for less than 1 second and
then release.
▪
Result:
The audible/visual alarm should
activate while the bar is being pressed and
turn off after being released. The reset button
should illuminate as soon as the sensor bar is
pressed, and turn off when the bar is released.
2.
Press the sensor bar for more than 1 second
and then release.
▪
Result:
The audible/visual alarm should
activate immediately and stay on after the
bar is released. The reset button should
illuminate.
3.
Press the reset button.
▪
Result:
The audible/visual alarm and reset
button light should go off.
4.
Press the sensor bar for more than 1 second
and then release.
▪
Result:
The audible/visual alarm should
activate immediately and stay on after the bar
is released. The reset button should illuminate.
5.
Depress and hold footswitch.
6.
Turn emergency power switch to on position
and activate any function (except drive/steer)
momentarily.
▪
Result:
The function should operate and the
platform audible/visual alarm and reset button
light should turn off.
Emergency stop
Drive/Steer controller
Platform railing
Manual box
Fall protection
anchorage
Platform control
console
Sensor bar
Fall protection
anchorage
Footswitch
Platform
assembly