Section 3 – Familiarization
Features and devices
3.4-8 Brake-release system
This system disengages the brakes manually before
you winch or tow the MEWP. Refer to
Section 6.3
for
the procedure. Refer to
Figure 05
and
Figure 06
for
the location of the brake-release system.
1
2
Figure 05
Brake-release system SJ40 T+/SJ45 T+
1
2
Figure 06
Brake-release system SJ61 T+/SJ66 T+
7
1
Brake hand pump
7
2
Brake auto-reset valve plunger
3.4-9 Secondary guarding electrical
(SGE)
This device prevents sustained involuntary operation
of the MEWP from accidental contact with the platform
controls. The audible/visual alarm lets personnel know
that pressure has been applied to the sensor bar.
WARNING
This device will not prevent a collision or injuries
that can result from a collision.
2
3
1
Figure 07
Secondary guarding electrical (SGE)
7
1
Sensor bar:
This bar is in front of the platform
control console. When you apply pressure to the
sensor bar, it stops all functions.
7
2
Reset:
This button is on the top left corner of the
platform control console. It illuminates when you
apply pressure to the sensor bar for more than 1
second. When you press this button, it stops the
audible/visual alarm.
7
3
Audible/visual alarm:
This alarm is on the
bottom of the platform control console. It goes
on when you apply pressure to the sensor bar.
SGE operation
1.
When you apply pressure to the sensor bar for
less than 1 second, the audible/visual alarm
goes on while the bar is pressed. All functions
stop. The audible/visual alarm goes off after the
sensor bar is released, and the functions are
available again.
2.
When you apply pressure to the sensor bar for
more than 1 second, the audible/visual alarm
goes on and the engine stops. All functions stop.
The reset button illuminates. The emergency-
power functions are available.
3.
After you remove pressure from the bar, press
the reset button to stop the audible/visual alarm
and make all functions available.
F
A
M
IL
IA
R
IZ
A
T
IO
N
Summary of Contents for SJ40 T+
Page 4: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 4 Notes ...
Page 10: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 10 Notes ...
Page 14: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 14 Notes ...
Page 22: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 22 Notes ...
Page 40: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 40 Notes ...
Page 64: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 64 Notes ...
Page 72: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 72 Notes ...
Page 83: ...SJ40 T SJ45 T SJ61 T SJ66 T 213201ACA 83 Section 7 Technical Diagrams and Specifications ...
Page 126: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 126 Notes ...
Page 128: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 128 Notes ...
Page 129: ...Cancer and Reproductive Harm https www p65warnings ca gov WARNING ...
Page 130: ...www skyjack com ...