SJ40 T+, SJ45 T+, SJ61 T+, SJ66 T+
213201ACA
57
Function tests
Section 4 – Inspections Before Operation
4.3-13 Do a test of the secondary guarding
electrical (SGE)
1.
Press the
sensor bar
8
for less than 1 second
and then release it.
▪
Result:
The audible/visual alarm goes on
while the bar is pressed and goes off after it
is released. The reset button illuminates when
the bar is pressed, and goes off when the bar
is released.
2.
Press the
sensor bar
for more than 1 second
and then release it.
▪
Result:
The audible/visual alarm goes on
immediately and stays on after the bar is
released. The reset button illuminates.
3.
Press the
reset
7
button.
▪
Result:
The audible/visual alarm and reset
button light go off.
4.
Start the engine.
5.
Press the
sensor bar
for less than 1 second and
then release it.
▪
Result:
The audible/visual alarm goes on
while the bar is pressed and goes off after it
is released. The reset button illuminates when
the bar is pressed, and goes off when the bar
is released.
6.
Press the
sensor bar
for more than 1 second
and then release it.
▪
Result:
The audible/visual alarm goes on
immediately and stays on after the bar is
released. The engine stops after 1 second.
The reset button illuminates.
7.
Press the
reset
button.
▪
Result:
The audible/visual alarm and reset
button light go off.
8.
Start the engine.
9.
Operate a drive function in the high torque
mode.
10.
Press the
sensor bar
for less than 1 second and
then release it.
▪
Result:
The function will stop while the bar is
pressed and the function will continue when
the bar is released. The audible/visual alarm
goes on while the bar is pressed and goes off
after it is released. The reset button illuminates
when the bar is pressed, and goes off when
the bar is released.
11.
Press the
sensor bar
for more than 1 second
and then release.
▪
Result:
The function will stop and the audible/
visual alarm goes on immediately and stays
on after the bar is released. The engine stops
after 1 second. The reset button illuminates.
12.
Start the engine.
13.
Operate a platform function (i.e., lift, extend, or
rotate).
14.
Press the
sensor bar
for less than 1 second and
then release it.
▪
Result:
The function will stop while the bar is
pressed and the function will continue when
the bar is released. The audible/visual alarm
goes on while the bar is pressed and goes off
after it is released. The reset button illuminates
when the bar is pressed and goes off when the
bar is released.
1
3
4
+
STOP
=
2
+
8
7
Summary of Contents for SJ40 T+
Page 4: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 4 Notes ...
Page 10: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 10 Notes ...
Page 14: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 14 Notes ...
Page 22: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 22 Notes ...
Page 40: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 40 Notes ...
Page 64: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 64 Notes ...
Page 72: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 72 Notes ...
Page 83: ...SJ40 T SJ45 T SJ61 T SJ66 T 213201ACA 83 Section 7 Technical Diagrams and Specifications ...
Page 126: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 126 Notes ...
Page 128: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 128 Notes ...
Page 129: ...Cancer and Reproductive Harm https www p65warnings ca gov WARNING ...
Page 130: ...www skyjack com ...