1.
Stuck or defective axle lockout valve 3H-65.
- Clean valve. Replace if defective.
2.
One or more counterbalance valves (CB12 or CB13) failed to shift or is defective.
- Clean valve. Check O-rings on valve. Repair or replace valve as required.
4.2-24 Axle Will Not Lock
NOTE
Axle is in constant float if boom is fully retracted and is below 15 de-
grees of elevation.
1.
Axle lockout valve 3H-65 is stuck in shifted position or is defective.
-
Clean valve. Check O-rings on valve. Check operation of valve. Repair or replace valve as
required.
2.
Bypassing or defective axle cylinders C6 and C7.
-
Check seals on cylinder. Replace as necessary. Replace cylinder if defective.
3.
Counterbalance valves (CB12 or CB13) out of adjustment or are defective.
-
Clean valve. Check O-rings on valve. Repair or replace valve as required.
4.3 Load Sensing System - CE
4.3-1 Green Power LED is not Flashing
1.
Loose or broken wires #60 and #02 at platform terminal block.
-
Check for connections. Check for voltage (12V).
2.
Load cell has lost its calibration.
-
Refer to calibration procedure for recalibration of load cell.
4.3-2 Load Cell red Alarm LED is ON (with platform empty)
1.
Load cell has lost its calibration.
-
Refer to calibration procedure for recalibration of load cell.
Summary of Contents for SJ61T
Page 1: ...TELESCOPIC BOOMS MODELS SJ61T SJ66T 194312AE February 2017 SERVICE MANUAL...
Page 42: ...Page 42 December 2007 Telescopic Boom Series Models SJ61T SJ66T 194312 Notes...
Page 230: ...Page 230 December 2007 Telescopic Boom Series Models SJ61T SJ66T 194312 Notes...
Page 231: ......
Page 232: ...www skyjack com P litelig lift l sninger av folk som bryr seg...