118
SJ82 T, SJ86 T
229040ABA
Section 4 – Troubleshooting Information
Electrical System
4.
Defective relay 57BCR.
Check relay. Replace if defective.
5.
Glow plug circuit not operating.
See “Glow Plug Circuit Inoperative” in this section.
6.
No fuel in fuel tank or fuel line obstructions.
Check fuel level and flow through lines. Fill or
repair if necessary.
NOTE
For other engine related problems, consult engine manufacturer’s manual.
4.2-5 Glow Plug Circuit Inoperative - Deutz D2011 diesel engine
1.
Defective glow plug fuse FU1 50 amp.
Check fuse. Replace if defective.
2.
Loose or broken wire #03 from start solenoid
57CCR to fuse holder FU1.
Check continuity. Replace if defective.
3.
Loose or broken wire #11A from fuse holder FU1
to relay 54ACR.
Check continuity. Replace if defective.
4.
Loose or broken wire #11B from relay 54ACR to
glow plugs.
Check continuity. Replace if defective.
5.
Loose or broken wire #54A from base terminal
strip to relay 54ACR.
Check continuity. Replace if defective.
6.
Loose or broken wire #11 from base terminal
block to relay 54ACR.
Check continuity. Replace if defective.
7.
Defective relay 54ACR.
Check relay. Replace if defective.
8.
Defective glow plugs.
Check glow plugs. Replace if defective.
NOTE
For other glow plug related problems, consult engine manufacturer’s manual.
4.2-6 Glow Plug Circuit Inoperative - Deutz D2.9 diesel engine
1.
Defective glow plug fuse FU2 100 amp.
Check fuse. Replace if defective.
2.
Loose or broken wire #03 from start solenoid to
fuse holder FU1.
Check continuity. Replace if defective.
3.
Loose or broken wire #11B from fuse holder
FU1 to relay 11CR.
Check continuity. Replace if defective.
4.
Loose or broken wire #11C from relay 11CR to
glow plugs.
Check continuity. Replace if defective.
To
order
go
to
Discount-Equipment.com