Section 5 – Procedures
Turret
Reprogramming the Existing Tilt Switch
Red LED
Green LED
Light Indicators
The set to zero button is located
on this face next to the harness
NOTE
The tilt circuit is only powered when the controls
are powered up.
1.
Turn the main disconnect switch to the ON
position
.
2.
Turn the base/off/platform key switch to the base
position
.
3.
Pull out both emergency stop buttons
.
4.
Verify switch is powered (red or green LED will
be continually blinking).
Red LED
Green LED
Red LED
Green LED
5.
Reprogram the Tilt Switch
a.
Press and hold the
set to zero button for
5 seconds.
Results:
Both LEDs
will be OFF.
Red LED
Green LED
b.
Both LEDs will flash.
Red LED
Green LED
IMPORTANT
Step “c” must be completed within a 5 second
period, or the switch will automatically exit
program mode and return to normal operation
using the previously stored data.
c.
Press and release the set to zero button 3
times.
d.
If the 5 second period has expired prior to
completion, repeat steps “a”, “b” and “c”.
e.
Observe program
delay / stabilization
time (only the red
LED will blink for 4
seconds).
Red LED
Green LED
f.
Both LEDs will flash for
1 second.
Results:
The switch is
learning the new zero
position.
Red LED
Green LED
g.
Both LEDs will turn on
solid for 1 second.
Results:
The new
zero position has been
learned.
Red LED
Green LED
h.
T
he green LED will flash and then the red
LED will turn on solid for 2 seconds.
Results:
The switch is verifying the new zero
position.
Red LED
Green LED
Red LED
Green LED
i.
T
he green LED will turn
on solid.
Results:
The switch
is ready for normal
operation.
Red LED
Green LED
6.
Turn the main power disconnect switch to the off
position
.
7.
Push in the emergency stop buttons
.
8.
Proceed to
Verify Tilt Circuit
.