225
SJ82 T, SJ86 T
229040ABA
Deutz Diesel Engines
Section 5 – Procedures
5.6-6 Deutz TD2.9L Fault Codes
Code SPN
FMI Blink Code
Error Identification
417
171
3
3-1-2
Sensor error SCR-System environment temperature.
DPF-System air inlet temperature, signal range check high.
418
171
4
3-1-2
Sensor error SCR-System environment temperature.
DPF-System air inlet temperature, signal range check low.
419
190
8
2-1-2
Sensor camshaft speed, disturbed signal.
420
190
12
2-1-2
Sensor camshaft detection.
Out of range, signal disrupted, no signal.
421
190
2
2-1-3
Offset angle between crank- and camshaft-sensor is too large.
422
190
8
2-1-2
Sensor crankshaft detection.
Out of range, signal disrupted or no signal.
423
190
12
2-1-2
Speed detection, out of range, signal disrupted or no signal.
455
975
5
2-3-8
PWM-Signal fan, open load or short-circuit ground.
457
975
3
2-3-8
PWM-Signal fan, short-circuit to battery.
458
975
4
2-3-8
PWM-Signal fan, open load or short circuit to ground
459
1639
12
2-3-8
Fan speed sensor, electrical error, signal disturbed or very low fan speed.
460
1639
0
2-3-8
Sensor error fan speed.
Signal range check high or engine speed resp. Fan speed too big.
461
1639
1
2-3-8
Sensor error fan speed, signal range check low or fan speed too low.
462
523602
0
2-3-8
High fan speed, warning threshold exceeded.
463
523602
0
2-3-8
High fan speed, shut off threshold exceeded.
464
97
3
2-2-8
Sensor error water in fuel, signal range check high.
465
97
4
2-2-8
Sensor error water in fuel, signal range check low.
472
94
3
2-1-6
Sensor error low fuel pressure, signal range check high.
473
94
4
2-1-6
Sensor error low fuel pressure, signal range check low.
474
94
1
2-1-6
Low fuel pressure, warning threshold exceeded.
475
94
1
2-1-6
Low fuel pressure, shut off threshold exceeded.
483
174
11
2-2-7
Fuel temperature not plausible.
486
523618
3
1-3-3
Sensor error gearbox oil temperature, signal range check high.
487
523618
4
1-3-3
Sensor error gearbox oil temperature, signal range check low.
488
523619
2
1-3-3
Physical range check high for exhaust gas temperature upstream (SCR-
CAT).
489
523619
2
1-3-3
Shutoff condition.
No detailed information!
500
523915
0
1-6-5
HCI dosing valve (DV1); overcurrent at the end of the injection phase
501
523915
12
1-6-6
HCI dosing valve (DV1): Powerstage over temperature.
502
523915
3
1-5-9
HCI dosing valve (DV1): Short circuit to battery.
503
523915
3
1-6-4
Short circuit to battery high side, HCI dosing valve (DV1).
504
523915
4
1-5-9
HCI dosing valve (DV1): Short circuit to ground.
505
523915
11
1-6-4
HCI dosing valve (DV1): Short circuit high side powerstage.