228
SJ82 T, SJ86 T
229040ABA
Section 5 – Procedures
Deutz Diesel Engines
5.6-6 Deutz TD2.9L Fault Codes
Code SPN
FMI Blink Code
Error Identification
624
523612
12
555
ECU reported internal software error.
625
523612
12
555
ECU reported internal software error.
627
523612
12
555
ECU reported internal software error.
628
523612
12
555
ECU reported internal software error.
629
523612
12
555
Diagnostic fault check to report the accelerator pedal position error.
630
523612
12
555
Diagnostic fault check to report the engine speed error.
631
523612
12
555
Error in the plausibility of the injection energizing time.
632
523612
12
555
Error in the plausibility of the start of energising angles.
633
523612
12
555
Diagnostic fault check to report the error due to non plausibility in ZFC.
634
523612
12
555
Diagnosis fault check to report the demand for normal mode due to an error
in the PoI2 quantity.
635
523612
12
555
Diagnosis fault check to report the error to demand for an ICO due to an
error in the PoI2 shut-off.
636
523612
12
555
Diagnosis fault check to report the error to demand for an ICO due to an
error in the PoI3 efficiency factor.
637
523612
12
555
Internal ECU monitoring detection reported error.
638
523612
12
555
Monitoring of Fuel Quantity Correction.
639
523612
12
555
Diagnostic fault check to report the plausibility error in rail pressure
monitoring.
640
523612
12
555
Diagnostic fault check to report the error due to torque comparison.
641
523612
12
555
Diagnosis of curr path limitation forced by ECU monitoring level 2.
642
523612
12
555
Diagnosis of lead path limitation forced by ECU monitoring level 2.
643
523612
12
5-5-5
Diagnosis of set path limitation forced by ECU monitoring level 2.
644
523612
3
5-5-5
Reported Over Voltage of Supply.
646
523612
4
5-5-5
Reported UnderVoltage of Supply.
648
523008
1
4-2-4
Manipulation control was triggered.
649
523008
2
4-2-4
Timeout error in Manipulation control.
654
2634
12
7-5-7
Early opening defect of main relay No detailed information!
656
2634
12
7-5-7
DFC for stuck main relay error No detailed information!
659
3226
2
8-1-3
Nox feed back fault detection No detailed information!
692
523752
0
7-5-8
Plausibiliti error during Rich to Lean switch over No detail informationen!
693
523752
0
7-5-8
Monitoring of Nox signal readyness No detail informationen!
714
523612
12
5-5-5
Diagnostic fault check to report WDA active due to errors in query-/response
communication.
715
523612
12
5-5-5
Diagnostic fault check to report ABE active due to undervoltage detection.
716
523612
12
5-5-5
Diagnostic fault check to report ABE active due to overvoltage detection.
717
523612
12
5-5-5
Diagnostic fault check to report WDA/ABE active due to unknown reason.
1513AA-8
To
order go
to