229
SJ82 T, SJ86 T
229040ABA
Deutz Diesel Engines
Section 5 – Procedures
5.6-6 Deutz TD2.9L Fault Codes
Code SPN
FMI Blink Code
Error Identification
720
98
2
2-1-1
Plausibility Check.
No detailed information!
732
100
3
2-2-4
Sensor error oil pressure; signal range check high.
733
100
4
2-2-4
Sensor error oil pressure sensor; signal range check low.
734
100
0
2-3-1
High oil pressure; warning threshold exceeded.
735
100
0
2-3-1
High oil pressure; shut off threshold exceeded.
736
100
1
2-3-1
Low oil pressure; warning threshold exceeded.
737
100
1
2-3-1
Low oil pressure; shut off threshold exceeded.
743
175
3
1-4-4
Sensor error oil temperature; signal range check high.
744
175
4
1-4-4
Sensor error oil temperature; signal range check low.
745
175
0
1-4-4
High oil temperature; warning threshold exceeded.
746
175
0
1-4-4
High oil temperature; shut off threshold exceeded.
747
1237
2
1-4-5
Override switch; plausibility error.
750
107
3
1-3-6
Sensor error airfilter differential pressure; short circuit to battery.
751
107
0
1-3-6
Sensor error airfilter differential pressure; short circuit to ground.
752
107
0
1-3-6
Air filter differential pressure; air filter cologged.
753
523919
2
6-9-4
DPF burner air pump pressure sensor, plausibility error.
755
523919
0
6-9-4
DPF burner air pump pressure sensor, pressure above upper shutoff
threshold.
758
523919
1
6-9-4
DPF burner air pump pressure sensor, pressure below lower shutoff
threshold.
761
523919
3
6-9-4
DPF burner air pump pressure sensor, short circuit to battery or open load.
762
523919
4
6-9-4
DPF burner air pump pressure sensor, short circuit to ground.
763
523920
2
7-1-6
Exhaustgaspressure upstream burner, plausibility error.
765
523920
0
7-1-6
Exhaust gas pressure upstream burner, pressure above upper shutoff
threshold.
770
523920
3
7-1-6
Exhaust gas pressure upstream burner, short circuit to battery or open load.
771
523920
4
7-1-6
Exhaust gas pressure upstream burner, short circuit to ground.
772
102
2
2-2-3
Pressure downstream charge air cooler, plausibility error.
774
102
1
2-2-3
Pressure downstream charge air cooler, pressure below lower physical
threshold.
776
102
3
2-2-3
Pressure downstream charge air cooler, short circuit to battery or open load.
777
102
4
2-2-3
Pressure downstream charge air cooler, short circuit to ground.
780
523699
3
1-1-3
Boost pressure control; negative governor deviation below limit.
781
523699
4
1-1-3
Learning value too high. No detailed information!
785
523889
3
1-1-3
Over temperature of device driver of pressure control valve. No detailed
information!
1513AA-9