230
SJ82 T, SJ86 T
229040ABA
Section 5 – Procedures
Deutz Diesel Engines
5.6-6 Deutz TD2.9L Fault Codes
Code SPN
FMI Blink Code
Error Identification
791
411
0
6-9-3
Delta pressure across venturi in EGR line above physical high limit.
793
411
0
6-9-3
Plausibility Check fault for deviation of desired and actual EGR-mass flow,
where the latter is calculated out of EGR Delta Pressure Sensor.
795
411
3
6-9-3
Sensor error differential pressure Venturiunit (EGR), signal range check low.
796
411
4
6-9-3
Sensor error differential pressure Venturiunit (EGR), signal range check high.
805
524025
14
8-4-5
Particulate filter regeneration.
(3x) over the max. has been aborted allowed recovery time.
Regeneration after time X is not successful (the error occurs when the
regeneration times).
806
524058
2
8-4-4
Particulate filter; regeneration not succesful.
807
3253
2
6-9-2
Differential pressure DPF, plausibility error.
809
3251
0
6-9-2
Differential pressure DPF maximum value is exceeded.
810
3251
0
6-9-2
Differential pressure sensor across DPF exceeds warning high limit.
812
3251
1
6-9-2
Differential pressure DPF, pressure below lower shutoff threshold.
813
3251
1
6-9-2
Differential pressure DPF, pressure below lower warning threshold.
814
3253
3
6-9-2
Electrical error differential pressure B58 (DPF). (Signal range check high).
815
3253
4
6-9-2
Electrical error differential pressure (DPF). signal range check low.
825
523009
9
2-5-3
The pressure relief valve (PRV) has reached the number of allowed
activations.
826
523470
2
1-4-6
Pressure relief valve is forced to open, perform pressure increase.
827
523470
2
1-4-6
Pressure Relief Valve (PRV) forced to open. Performed by pressure increase.
828
523470
12
1-4-6
Pressure Relief Valve (PRV) forced to open. Shutoff conditions.
829
523470
12
1-4-6
Pressure Relief Valve (PRV) forced to open. Warning conditions.
830
523470
14
1-4-6
Open Pressure Relief Valve (PRV).
831
523470
11
1-4-6
Pressure Relief Valve (PRV) error; Rail pressure out of tolerance range.
832
523470
11
1-4-6
Rail pressure out of tolerance range.
The PRV can not be opened at this operating point with a pressure shock.
833
523009
10
2-5-3
Open time of Pressure Relief Valve (PRV) for wear out monitoring had
exceeded.
834
523906
5
7-6-1
Electrical fuel pre - supply pump; open load.
835
523906
12
7-6-1
Electrical fuel pre - supply pump. ECU powerstage over temperature.
836
523906
3
7-6-1
Electrical fuel pre - supply pump; short circuit to battery.
837
523906
4
7-6-1
Electrical fuel pre - supply pump. Short circuit to ground.
847
1176
0
1-3-9
Pressure sensor upstream turbine, Physical Range Check high.
848
1176
1
1-3-9
Pressure sensor upstream turbine, Physical Range Check low.
849
1176
3
1-4-1
Pressure sensor upstream turbine, signal range check (SRC) high.
850
1176
4
1-4-1
Pressure sensor upstream turbine, signal range check (SRC) low.
856
523613
0
1-3-4
Rail pressure metering unit, Positive governor deviation.