5.6-6 Deutz TD2.9L Fault Codes
Code SPN
FMI Blink Code
Error Identification
916
523721
2
6-8-9
Sensor DEF supply module temperature; plausibility error (normal condition).
917
523721
2
6-8-9
Sensor DEF supply module temperature; plausibility error (cold start
condition).
918
523981
11
2-4-3
SCR plausibility, OBD and diagnosis; Stuck in range check of DEF tank
temperature sensor.
DEF-tank without heating function (heating phase).
919
523330
14
1-3-1
Immobilizer status; fuel blocked.
920
523330
14
1-3-1
DFC to block the fuel by Sia. No detailed information!
921
523330
14
1-3-1
DFC to indicate that TEN-code or UC-code received if ECU is learned.
No detailed information!
922
523330
14
1-3-1
DFC to indicate that no code is received via CAN. No detailed information!
923
523330
14
1-3-1
DFC to indicate that wrong code is received. No detailed information!
925
523720
8
1-4-8
DEF supply module heater temperature; duty cycle in failure range.
926
523720
8
1-4-8
DEF supply module heater temperature; duty cycle in invalid range.
927
523721
11
6-8-9
Urea supply module temperature measurement not available.
928
523722
8
6-9-1
DEF supply module PWM signal; period outside valid range.
929
523722
8
6-9-1
Detect faulty PWM signal from Supply Modul.
930
523721
8
6-8-9
DEF supply module temperature; duty cycle in failure range.
931
523721
8
6-8-9
Urea supply module temperature; duty cycle in invalid range.
932
29
3
1-2-6
Handthrottle idle validation switch; short circuit to battery
935
91
3
2-2-6
Sensor error accelerator pedal. signal range check high.
937
29
4
1-2-6
Handthrottle; short circuit to ground.
940
91
4
2-2-6
Sensor error accelerator pedal. Signal is below the range.
942
523921
3
7-1-4
Sensor error burner temperature; signal range check high.
943
3532
3
1-2-7
Sensor error DEF tank level; signal range check high.
944
523921
4
7-1-4
Sensor error burner temperature; signal range check low.
946
1079
13
2-8-2
Failure of sensor supply voltage 1.
947
1080
13
2-8-2
Failure of sensor supply voltage 2.
948
523601
13
2-8-2
Failure of sensor supply voltage 3.
956
677
3
5-1-2
Starter relay high side. Short circuit to battery.
957
677
4
5-1-2
Starter relay high side short circuit to ground.
958
677
5
5-1-2
Starter relay low side no load error.
959
677
12
5-1-2
Starter relay powerstage over temperature.
960
677
3
5-1-2
Starter relay low side short circuit to battery.
961
677
4
5-1-2
Starter relay low side short circuit to ground.
965
523922
3
7-1-5
Burner shut of valve; short circuit to battery.
969
624
5
5-1-3
SVS lamp; open load.