SJ82 T, SJ86 T
229040ABA
Deutz Diesel Engines
Section 5 – Procedures
5.6-6 Deutz TD2.9L Fault Codes
Code SPN
FMI Blink Code
Error Identification
1219
524018
14
7-8-6
HMI engine derate service state.
DPF wasn’t regenerated, power reduction phase 1 (manuell regeneration
request).
1220
524022
14
7-8-6
HMI engine derate stop state.
DPF wasn’t regenerated, power reduction phase 2 (manuell regeneration
request).
1222
190
14
2-1-2
Camshaft- and Crankshaft speed sensor signal not available on CAN.
1223
51
5
5-9-4
Actuator EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); open load.
1224
51
6
5-9-4
Actuator EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); over current.
1226
51
3
5-9-4
EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); short circuit to battery.
1227
51
3
5-9-4
EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); short circuit to battery.
1228
51
4
5-9-4
EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); short circuit to ground.
1229
51
4
5-9-4
EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); short circuit to ground.
1230
51
6
5-9-4
Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); Overload by
short-circuit.
1231
51
11
5-9-4
Power stage overtemperature due to high current.
1232
51
4
5-9-4
actuator AGR valve (2.9;3.6) throttle valve (4.1;6.1;7.8); Voltage below thresh-
old.
1239
523984
3
7-8-8
UB7; Short circuit to battery error of actuator relay 7.
1241
523986
4
1-7-6
UB6; Short circuit to ground actuator relais 6.
1242
523987
4
7-9-1
UB7; Short circuit to ground actuator relay 7.
1247
524019
11
8-6-2
Burner Control; Air Line - Blocked Air Pump; air lines blocked.
1248
523910
9
6-9-5
Burner Control; Air Pump - CAN Lost Air Pump; CAN communication lost.
1249
523910
7
6-9-5
Air pump; CAN communication interrupted no purge function available.
1250
523910
12
6-9-5
Air Pump; internal error.
1252
523910
0
6-9-5
Air Pump; operating voltage error.
1254
524014
1
8-5-8
Air inlet EPV - pressure too low.
Air pressure glow plug flush line; below limit.
1255
524013
7
8-5-7
Burner Control; Flame lost max.
Burner operation is interrupted too often.
1257
523915
7
8-5-3
HCI dosing valve (DV1); blocked open.
1258
524016
11
8-5-9
Burner Control; HFM - Electrical Fault HFM sensor; electrical fault.
1259
524016
2
8-5-9
Burner Control; HFM - Plausibilitätsfehler 1 Amount of air is not plausible to
pump speed.
1261
523910
6
6-9-5
Burner Control Air Pump; over current Air pump electrically overloaded.
1262
523922
7
8-5-4
Burner Control; Shut-off Valve - Blocked closed Burner Shut Off Valve;
blocked closed.
1263
524021
11
8-6-4
Burner Control; Fuel line ShutOff downstream - broken Burner fuel line pipe
leak behind Shut Off Valve.