57
SJ82 T, SJ86 T
229040ABA
Electrical Parts List
Section 3 – System Component Identification and Schematics
Index
No.
Skyjack
Part No.
Description
01ACR
127131
RELAY, 12 Volt 40 Amp (E-pump)
01CR
127131
RELAY, 12 Volt 40 Amp (E-pump)
07CR
127131
RELAY, 12 Volt 40 Amp (E-pump enable)
08CR
127131
RELAY, 12 Volt 40 Amp (Engine start interlock)
08CR1
127131
RELAY, 12 Volt 40 Amp (Dump valve interlock)
09CR
127131
RELAY, 12 Volt 40 Amp (ECU power or Telematics)
11CR
127131
RELAY, 12 Volt 40 Amp (Cold start)
17ACR1
127131
RELAY, 12 Volt 40 Amp (Steer reverse)
17ACR2
127131
RELAY, 12 Volt 40 Amp (Steer reverse)
19CR
127131
RELAY, 12 Volt 40 Amp (Boom down throttle)
21CR
127131
RELAY, 12 Volt 40 Amp (Dump valve)
27CR
127131
RELAY, 12 Volt 40 Amp (Tilt alarm)
45CR1
127131
RELAY, 12 Volt 40 Amp (Torque mode)
45CR2
127131
RELAY, 12 Volt 40 Amp (Torque mode)
49CR
127131
RELAY, 12 Volt 40 Amp (Horn)
54ACR
127131
RELAY, 12 Volt 40 Amp (Cold start)
56ACR
127131
RELAY, 12 Volt 40 Amp (Fuel pump)
57ACR
127131
RELAY, 12 Volt 40 Amp (Anti-restart)
57ACR1
127131
RELAY, 12 Volt 40 Amp (Generator interlock)
60CR
127131
RELAY, 12 Volt 40 Amp (Main power enable)
76ACR
127131
RELAY, 12 Volt 40 Amp (MIL light)
77CR
127131
RELAY, 12 Volt 40 Amp (E-pump enable)
77CR1
127131
RELAY, 12 Volt 40 Amp (Hourmeter/counter)
78CR
127131
RELAY, 12 Volt 40 Amp (High idle)
79CR
127131
RELAY, 12 Volt 40 Amp (Low idle)
82CR
127131
RELAY, 12 Volt 40 Amp (Overload light)
86CR
127131
RELAY, 12 Volt 40 Amp (Oil cooler)
120CR
127131
RELAY, 12 Volt 40 Amp (Low capacity enable)
- ANSI/CSA
120CR
127131
RELAY, 12 Volt 40 Amp (High capacity light)
- CE & AS
3.6 Electrical Parts List
CONTROL (B+)
NORMALLY
CLOSED
CONTACT
SUPPLY (B+) (Common)
GROUND (B-)
NORMALLY
OPEN
CONTACT