8. TECHNICAL SPECIFICATIONS
Input Voltage: 120V AC, 60Hz
Standby Current: 3mA
Maximum Rating: 15 Amps
Maximum Ballast Load: 500W
Maximum Tunsgsten Load: 800W
Maximum Resistive Load: 1500W
Operating Frequency: 318MHz
Range: Up to 500 feet in open area.
Minimum Load: 10W
o
o
Operational Temperature: -4 F - 140 F
o
o
(-20 C - 60 C)
Humidity: 5%-95%
7. ERASING TRANSMITTERS
You may erase a transmitter or sensor from the
module, but you cannot erase a specific device
directly, you must erase all the wireless devices,
then program the ones you want to keep. Follow
the instructions below to erase programmed
transmitters / sensors.
1. Power off the Plug-In Module (Indoor / Outdoor)
by removing it from the AC socket.
2. Press and hold the SET button, while plugging in
the module to an AC outlet.
3. The red LED will be on first, then flashes rapidly
for 1 second, then on and off.
4. You may release the SET button, now
you have successfully erased all the
devices from the lighting receiver.
5. Now you have successfully erased all
the devices.
CUSTOMER SERVICE
17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3
Email:support@skylinkhome.com
http://www.skylinkhome.com
P/N. 101Z700-001 R1
Patent Pending
©2010 SKYLINK GROUP
6. COUNTDOWN TIMER OPERATING MODE
If a transmitter or a sensor is programmed to the Plug-In ON/OFF Control
(In/Outdoor) under the countdown timer mode, when that transmitter is
activated, the load connected will be on for the predetermined timer interval,
the LED on the Plug-In ON/OFF Control
will also be on. After the timer
interval, the load will be turned off.
Pressing a programmed button for
ON/OFF mode can override timer
operation.
Press and hold the SET
button while plugging
it in to an AC socket
5. SET TIMER DURATION (CONT)
Note: Once the number of flashes reaches 5, it will stay at this setting. If
you would like to go back to other settings, such as 1 flash, release the
button and repeat from step 1 to start over.
Once a transmitter (button) is programmed for timer mode, activating this
programmed transmitter (button) will turn on the light for the specified
timer duration.
During a timer count down, if the module receives another signal for timer
operation, the timer will start again and overrides the previous timer,
therefore, extending the On period by another timer interval.
To stop timer count down, press a programmed button for ON/OFF mode.
9. FCC
The device is approved by the FCC and it complies with Part 15 of the FCC Rules.
Its operation is subject to the following two conditions :
1. This device may not cause harmful interference.
2. This device must accept any interference that may cause undesired operation.
WARNING:
Changes or modifications to this unit not expressly approved by the party responsible
of compliance could void the user’s authority to operate the equipment.
11. CUSTOMER SERVICE
12. ACCESSORIES
The Skylink
System consists of many other devices such as
SkylinkHome Remotes, Motion Sensor, ON/OFF Wall Switch, Wall
Dimmer, Plug-In Dimmer with or without Repeater, Plug-In ON/OFF
Control (Outdoor/Indoor), Screw-In Dimmer, ON/OFF/Dimming Control,
ON/OFF Control, Smart Button Garage Door Control, etc. Please visit
Skylink website at www.skylinkhome.com for more information.
TM
Home
TM
TM
10. WARRANTY
If, within one year from date of purchase, this product should become defective
(except battery), due to faulty workmanship or materials, it will be repaired or
replaced, without charge. Proof of purchase and a Return Authorization are required.
If you would like to
-
find out the up-to-date specifications
-
know more about features and applications
-
download documents, i.e. user’s instructions
-
order Skylink products
or if you have difficulty getting products to work, please:
1. visit our FAQ section at www.skylinkhome.com, or
2. email us at support@skylinkhome.com, or
3. call our toll free at 1-800-304-1187 from Monday to Friday, 9 am to 5 pm EST.
Fax (800) 286-1320