18
MILAN
MILAN HUB
MILAN POWER
(NO Sealpac)
Inspection
• After each use (training,
demonstration etc.) or
• If there are doubts on
the devices function /
safety or
• At least yearly
• Devices which are used
regularly, e.g. as training
equipment, may have short-
er inspection intervals.
• Before every use
Competent person
(trained acc. DGUV 312-
906 or a
regional corresponding
education)
Service LEVEL 2
MILAN service, cleaning
inside, replacement of parts
(acc. to SKYLOTEC training,
the included instruction
and a detailed service
documentation)
• at least every 5 years or
• After a rescue scenario
or
• After 2000m descending
• technical uncertainties
• documentation should be
done in HOMEBASE
SKYLOTEC MILAN Ser-
vice Level 2 training
Replacement of the brake:
• At least after 10 years (Only
by SKYLOTEC or SKYLOTEC
Competent service stations
Level 2 trained)
• Inspection / replacement
following the instructions on
the MILAN Service Level 2
service training
Replacement of textile com-
ponents (Ropes, harnesses,
slings): At least after 10 years
Service LEVEL 3
na.
na.
na.
Max. lifespan
Max. 20 years from
manufacturing date (month
+ year) (if the replacement
after 10 years has been
done)
Devices which are used
regularly, e.g. as training
equipment, may have a
shorter service life.