E_MH_Mounting_instructions_Skylux_Climalux
01/11/2017
14/36
Gutter
Multiple gutter combinations are possible.
Use the load graphs on page 31-33 or calculate using the Climafast calculation application:
gutter combination (with reinforcement profile
GX (+ V822)
GX + GLX (+ V822)
GX + GR (+ V822)
Make sure there is a play of 10 mm if the gutter combination is to be installed between two walls. The 5 mm
clearance on each side is required for the installation of the slide ends.
Pre-drilling is required to install the U-brackets if the gutter (rafter) is reinforced with a steel profile. The use of
strong self-drilling screws is recommended.
* The reinforcement profile V822 is not supplied. It can be bought at any local hardware store.
We recommend treating the reinforcement profiles with an anti-corrosion product.
160
115
90,5
211,58
V822
GX
150
176
51,58
90,5
V822
GX
GLX
90,5
160
51,58
211,7
61,5
GX
GR
V822