01/11/2017
19/36
E_MH_Mounting_instructions_Skylux_Climalux
Wall profile
Components
Preparation
Install a lead slab to ensure a waterproof junction to the walls. Make a slot in the walls against which the
conservatory roof is to be installed (page 8). Install a lead slab or zinc flashing.
Drill a hole in the wall profile MX at 250 mm from the ends and subsequently every 500 mm at the top indication
line with a diameter in function of the chosen fixing material. Drill also a hole every 500 mm in the bottom
indication line and start at 30 mm from the edge.
Important: Slight the rubber C1CX in the profile MX before mounting.
Installation
Fix the wall profile using the adapted anchoring. The holes in the bottom wall profile correspond to the height HM
+ 19 mm and HM + 109 mm on the wall.
Finish the top side of the wall profile with silicone and with a lead slab or zinc flashing built-in in the wall.
143,6
30
39,5
19
90
98°
C1CX
MX
500
250
30
500
500
500
500