E_MH_Mounting_instructions_Skylux_Climalux
01/11/2017
22/36
d1 (= 550 mm max)
d2
D
D = d1 + 110 + d2
ZSC (2x)
LGDX
ZSG
GX
MX
ZSG (1x)
ZSG (1x)
Rafters and side rafters
Installation on the gutter rafter GDX for roof with overhang
Mark out the positions of the rafters on the gutter rafter GDX and check the axis-on-axis measurements.
The rafter DX rests on the gutter rafter GDX at the gutter side. Every rafter is fastened with 2 fixing profiles LGDX
and ZSG screws.
Every rafter is fastened on to the wall side with 1 lacquered ZSG screw. We recommend to pre-drill with Ø 4 mm
to avoid lacquer damage. The gutter GX is fastened on to the rafters with 2 ZSC screws (with sealing) per rafter
at the top side and 1 lacquered ZSC screw at the bottom side. Foresee a spacer AX at the gutter and wall side
between the rafters (page 23).
20
ZSC (2x)
GX
ZSG (3x)
GDX
LGDX
DX