E_MH_Mounting_instructions_Skylux_Climalux
01/11/2017
6/36
Measuring your Climalux pitched roof
Measurement
Determine the height difference H.
The height difference H is the difference between the bottom side of the wall profile MX and the bottom surface
of the gutter combination. The stop lip for the window is not included in the calculation. The standard roof
inclination is 8°. Other inclinations are possible between min 5° and max 10°.
The height h is always 144 mm.
Determine the depth (fig 2, page 7)
Measure horizontally from the wall to the inner side of the support post to determine the roof depth D. The
additional depth of gutter GX is 160 mm, or of the gutter with ornamental frame GLX is 176 mm for a Climalux.
For a construction with eave, please consult page 22.
Determine the width B (fig 2, page 7)
The width B of the Climalux is the distance between the outer side of the side rafters. If the Climalux is installed
between two walls and a gutter with screwed-on gutter end-pieces is used, you can deduct 5 mm per side from
width B, as the screws for the gutter end piece require additional width and additional clearance is recommended.
These measurements can be used to calculate all other measurements using the Climafast calculation application,
which is available free of charge from Skylux. We strongly recommend the use of the calculation application.
All possible exceptions are taken into account. The correct cutting lengths are provided and only correct
combinations are suggested. The list of measurements for sizing is always provided with the materials.w
160
176
11
5 150
h = 144
H
D
B
H
D