Wall profile
Parts
Preparation
Make a slot in the wall against which the conservatory roof must be installed (see page 16). Install a lead slab
or zinc flashing. Drill a hole on the indicated line in the bottom wall profile MB at 250 mm from the ends and,
subsequently, every 500 mm. The diameter of the hole should be selected depending on the selected fixing
material. Repeat this every 1000 mm for the top wall profile MT. Slide seal C1CX in the opening of the top wall
profile MT. Slide-in thermal bridges Y16P are used to fasten the bottom and top wall profiles.
The thermal bridges must not be slid in continuously over the full length. A 250 mm length every 250 mm is
sufficient. The Y16P is used to regulate the height. The number of thermal bridges Y16P that are slid on to each
other between the bottom wall profile (MB) and the top wall profile (MT) is determined in relation to the glazing
thickness and the conservatory roof pitch (see the table on page 12).
Assembly
Fasten the assembled wall profile using the adjusted anchors. The holes in the bottom wall profile match height
HM + 70 mm on the wall.
Finish the top of the top wall profile MT with silicone and with a lead slab or zinc flashing built into the wall. Install
hinge profile S1 or S2 in the bottom wall profile.