20/11/2020
51/88
E_MH_Installation_instructions_Skylux_Climax
Rafters and side rafters
The following (side) supports are possible:
Sheet supports TP (white) are used for roofs with plastic glazing. Sheet supports TPG (green) are used for roofs
with glass (single or double glazing). A steel reinforcement profile must be slid into the supports for a large span
or an expected heavy snow load. Check the length of the support in relation to the glazing and the snow and wind
load. See the graphs on page 77 - 80 or use the Climafast calculation application.
Support
Support
with
reinforcement
D1 + TP(G)
D1 + V642 + TP(G)
D2+ TP(G) D2 + V1044* + TP(G)
D3+ TP(G) D3 + PL105* + TP(G)
The steel reinforcement is 100 mm shorter than the length of the support. No reinforcement profiles are used in
the side supports.
* Reinforcement profiles V1044 or PL105 are not supplied. They can be bought at any local hardware shop.
We recommend treating the reinforcement profiles with an anti-corrosion product.
60
75
60
40
2
TP(G)
D1
V642
60
115
40
100
4
TP(G)
D2
V1044*
115
100
60
5
TP(G)
D3
PL105*