Measuring your Climax pitched roof
3
H
H
M
H
G
H
N
D
h
Installing the Climax post and the Climax PV base plate.
- Determine point O1.
- Determine O2. The distance O1 - O2 = conservatory width “B”.
- Draw a line with chalk using the 3/4/5 rule and determine point
P1. The distance O1 - P1 is the depth = D.
(Refer to item 3 below.)
- Repeat the same calculations for P2
- Measure the distance (P1 - P2), which must be equal to (O1 -
O2) as an additional check.
- The base plate can be slid through the slotted holes in order
to position the base plate properly.
- The U for the base plate can be moved 20 mm either way to
allow proper adjustment.
The 3/4/5 rule.
- Determine the auxiliary point C1 based on O1 at a distance
of 4 metres
- Use a 3 metre string and a piece of chalk to draw a circle from
point O1.
- Use a 5 metre string to draw a circle from point C1
- The 2 circles intersect at C2.
- Line O1 - C2 should be at a perfect right angle to your wall
(line C1-O1).
The difference in height H and depth D for the veranda.
HM = The height from the floor and the bottom side of the
wall bottom (MB) measured at the back of the veranda.
HN = The slope of your veranda floor.
HG + HN = Installation height from the bottom side of the gutter.
This is also the height for the windows or the
length of the posts.
H = HM - HG
h = Wall profile height
1
D
O
2
B
O
1
P
1
P
2
C
2
C
1
3 m
4 m
5 m
D
20 mm
300
mm
300 mm
P
1
100
mm
95 mm
95 mm
P
2
100
mm
2