E_MH_Instalation_instructions_Skylux_Climax_Panorama
20/11/2020
28/60
Supports and side supports
Supports and side supports
Preparation
Cut the plastic sheet supports TP or TPG to the right length
while retaining the precut part. You may have to make this
cut-away yourself depending on the cutting. This cut-away is
required for proper water drainage of the end profiles.
Cut supports D1 or D2 to the proper length at a right angle.
Cut the reinforced profiles to the right length and slide them
into the aluminium support profiles. For regular installation
using plastic sheets, the length of the reinforced profiles
should be the same as the support length.
For in
stallation using glazing, the reinforced profiles should
be 100 +mm shorter than the supports (installation with con-
nectors and spacers; see page 30).
Screw the stop profiles to the precut side of the sheet sup-
ports using the included parker screws PS 48 (4.8 x 25 mm).
Slide the sheet supports TP(G) into the aluminium supports
D1 or D2.
Adaptor profile Y25 or Y32 should be slid in depending on
the glazing thickness (see the table on page 55).
Y25/Y32
TP(G)
20 mm
20 mm
30 mm
8 mm
TPG
D1/D2
V642/V1044
25 mm
ZSB
K
ZSB
TP(G)
PS 48
TP(G)
D1/D2/D3
TP