IMPORTANT
Never clean the machine if connected to the electric network. To clean unplug the
machine. Before to li
ft
the Crown, be sure the motor is completely s
ti
ll.
3.3 Cleaning
The extractor must be totally cleaned and hygienized any
ti
me as follows:
- Before to use it the
fi
rst
ti
me.
- A
ft
er each day opera
ti
on.
- Any
ti
mes the extarctor has remained out of opera
ti
on for a long period.
Some extractor parts may be removed for cleaning:
- Cup
- Lid
- Sieve
- Liquid chamber
- Small crown
- Large crown .
All removable parts shall be removed and cleaned with water and neutral ph detergent.
Below
fi
nd the procedure to remove the moving parts:
3.3.1 Switch OFF the machine and unplug it.
3.3.2 Remove the Lid #.01 (pict 01 ) , the Crown #.09 or #. 10 (Pict.01) , and a
ft
er remove
the Liquid Chamber #. 02 (Pict 01 ).
3.3.3 Wash all the parts with water and soap, then dry them.
3.3.4 To assemble the parts proceed following the inverse procedure.
IMPORTANT
Never use water jets to wash rhe extractor.
13
5. Analysis and Problems Solving
5.1 Problem, causes and solu
ti
ons
The Juice Extractor Mod. ESB were designed to operate with the need of minimum
maintenance but the natural wearing caused by long use of the equipment may occasionally
cause some malfunc
ti
ons.
If such problem occurs with your mixer refer to Table 02 in which the most common
situa
ti
ons are listed with recommended solu
ti
ons.