IMPORTANT
The equipment has a safety system to protect the operator integrity. The
equipment shall be used in accordancewith the item 3 “Operation” Other
procedures are unsafe and shall not be used.
IMPORTANT
The expeller dish # 01(Pic.03) must always to be used with any Disc type # 02
(Pic.03). Before to open the Disc Chamber Lid # 05 (Pic.03) make sure the Disc # 02
(pic.03) is completely stop.
06
02
05
B - the second system actuate when the Stumper # 03 (Pic. 04) is out of the Throat # 04
(Pic. 04), then the processor is switched OFF and will turn ON only when the stumper
returns to its place inside the throat.
IMPORTANT
The product offload occurs by gravity, therefore the offload opening shall always
be free to avoid the product to remain accumulated inside the machine. Clean
regularly the Disc Chamber inside to avoid residues to accumulate and cause the
offload opening to be obstructed.
IMPORTANT
Before to press the Reset Button make sure the ON/OFF Switch to be placed
position “O” (meaning OFF position).