Hardwired Zone
Connections
SYSTEM
OVERVIEW
SYSTEM
OVERVIEW
5
4
About
the
Backlight
Indicators
of
Panic
Key
Wiring Overview
Zone 1、Zone 2 and Zone 3 are the EOLR supervised zones that supports both open circuit
and closed circuit devices and has a response time of 300msec . Maximum zone resistance:
11000 ohms,plus EOLR
Connect closed circuit devices in series in the high (+) side of the loop. The EOL resistor
must be connected in series with the devices, following the last device.
Connect open circuit devices in parallel across the loop. The 10000-ohm EOLR must be
connected across the loop at the last device.
Refer to the Hardwired Zones Connections diagram.
the
Hardwired
Zones
Connections
Diagram
EOLR
(
End
of
Line
Resistor
):
If the EOLR is not at the end of the loop, the
zone will
not
be properly supervised, and the system may not respond
to an open
circuit on the zone.
!