14
D250
Operating Program
Here is the detailed procedure to make the charger work. All the screens and operations
will take Li-Po BALANCE CHARGE program for example,
Note: We will explain one channel as the operating procedure
of Channel 1 and Channel 2 is identical.
1.
Connection
Connecting to power source
There are two kinds of inputs for SKYRC D250, DC 11-18V and AC 100-240V.
A. Operating in AC mode
SKYRC D250 comes with built in switching power supply. You can connect the AC
power cord directly to the main AC socket. (100-240V AC).
Note: The charging power in AC mode is 250W totally for Channel 1, Channel 2 and
Power supply.
In AC mode, it supports Power Distribution. The total power for Channel 1, Channel
2 and power supply is 250W. You could set the Max Power for one channel (Take
Channel 1 for example)as following,
And the DC power supply will take the rest power automatically (For example, if you set
channel 1 as 120W and channel 2 as 50W,the power supply will be 80W).
If Channel 1 and Channel 2 are both charging, you can’t change the power
distribution.
If Channel 1 is charging, you can change power of Channel 2 and Channel 1,
the power supply will take the rest power automatically.
B. Operating in DC mode
Please connect SKYRC D250 with AC/DC power supply by supplied DC input cable. Also
you could use terminal clips with DC connectors, for attaching directly to 12V car
batteries. It is critically important that you use either a fully charged 13.8V car battery or a
high quality AC/DC power supply in the range of 11-18V DC output with minimum power
300W or higher to insure reliable performance.
1).
NOTE1:
NOTE2:
C H 1 : 1 2 0 C H 2 : 5 0 W
D C S U P P L Y : 8 0 W
C H 1 : 1 2 0 C H 2 : 5 0 W
D C S U P P L Y : 8 0 W