PEPPER CROSS LIGHT
16.
Starting at the main riser, loop
the line bundles in the shape of
a figure-eight. Use silicone-
based rubber rings to fix the
line bundles.
Make sure that there is no line
knot in the line loop. Make sure
to leave approx. 30 cm free to
the first figure-eight.
This length is needed for the
final line loop.
17.
Now place the line bundles in
the designated line pocket inside
the reserve container.
18.
Secure the fourth and final
rescue flap with the remaining
line length from step 16.
The rescue system is now
packed!
14 .
Now place the reserve chute
like a snake in the container,
take care to use the full
length and width.
15.
Now close the first three
rescue flaps and secure
them with a small line loop.
This method will avoid burns
from a deployment later sin-
ce the bundle of lines will be
released first and will not
come in contact with the
material.
Packing Instruction
39
38
Packing Instruction
14
15
18
17
16
EN