IDP 100 Modem Series - Developer Guide
T203, Version 04 38
©
SkyWave Proprietary
5.4.20 S93
– Captured Record Properties - Length
Description
This command returns the number of valid data fields in the capture trace record. The
size identifies the number of valid S registers used to hold the capture record data.
Syntax
ATS93?
Information Response Syntax
<size>
Parameters
A decimal number of size 0 to 24
Result Codes
OK
Success
ERROR
5.4.21 S94
– Captured Record Properties - Data Sign
Description
This command returns a 32 bit value that contains a bitmap to identify if each data
record in the capture record is signed or unsigned. S93 reports the data size and the
number of valid bits reported by S94. The first bit (bit 00) corresponds to the first
capture record data longword located in S100.
Syntax
ATS94?
Information Response Syntax
<signedBitMap>
Result Codes
OK
Success
ERROR
Summary of Contents for IDP 100 Series