IDP 100 Modem Series - Developer Guide
T203, Version 04 50
©
SkyWave Proprietary
<priority>
Always 0 for to-mobile messages
<sin>
Service identification number
<state>
2 Rx Completed (Entire message received and available, but not yet
read)
3 Rx Retrieved (Message has been retrieved/read (via
%MGFG
) and
message data is still available)
<length>
Total message length in bytes (including SIN byte and MIN byte)
<dataFormat>
0 Transfer mode to be entered after information response to transfer
message data (and AT command mode automatically resumes once
the data transfer is complete)
1 Text format message data (bounded by double-quote (") characters)
included in information response
2 ASCII-Hex format message data included in information response
3 Base64 (MIME) encoded message data included in information
response
<data>
Message data, formatted as specified by
<dataFormat>
See above for details
Example
The examples below all represent identical message (with message data ¡Olé!)
Text Example:
%MGFG="FM31.63",1
%MGFG: "FM31.63",31.63,0,17,2,6,1,"\ADOl\82!"
ASCII-HEX Example:
%MGFG="FM31.63",2
%MGFG: "FM31.63",31.63,0,17,2,6,2,AD4F6C8221
Base64 Example:
%MGFG="FM31.63",3
%MGFG: "FM31.63",31.63,0,17,2,6,3,rU9sgiE=
Block mode Example:
%MGFG="FM31.63",0
%MGFG: "FM31.63",31.63,0,17,2,6,0
(then obtain AD4F6C8221 via transfer)
Summary of Contents for IDP 100 Series