4. Opening The Generator
Mark the side of the nacelles cover which is facing the shaft. Only in this direction the
cover will fit to the turbine again after dismounting.
Open up the nacelle by loosening all the screws highlited in yellow. Keep the turbine in
the position shown under Fig. 1.
3. Visual Check
Place the turbine as shown in the picture. Do not place the turbine on the back. This
would lead to the metal deforming once the cover is removed.
Check the turbine for any potential visual damages.
Check the generator by turning the shaft by hand. If needed you may conect the genera-
tor to a 25 V DC power source. The generator should consume about 0.5 A .
Any visual damage on the turbines packaging must be reported to the shipper immedi-
atly upon receiving the package! Any damage of the turbine itself (not visible fromt he
outside) or missing parts must be reported within five (5) days after receiving!
Page 45
| SkyWind Installation Handbook