5.1 DC-Coupled Output Clock Terminations
1.425V to 3.63V
OUTx
OUTx
Zo=50Ω
Zo=50Ω
Set output driver
to 50Ω mode.
Figure 5.1. LVCMOS Termination, Option 1
1.425 to 3.63V
OUTx
Rs
OUTx
Zo=50Ω
Zo=50Ω
Rs
Rs = Zo – Rdrv
Set output driver
to 25Ω mode.
Figure 5.2. LVCMOS Termination, Option 2
Si5357 Reference Manual • Output Clock Terminations
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
12
Rev. 0.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 26, 2021