Register field name
Address Base
Bit
length
R/W/RW
Description
Device
mode
IDP_CFG_SEL
66
0
1
RW
divider configuration bank select. The di-
vider supports dynamically switching be-
tween two complete configurations. This
is controlled through IDP_CFG. Reconfi-
guration should be done on the unselec-
ted bank. If IDP_CFG is 0 (running based
off bank A), then bank B may be freely
reconfigured and once ready all changes
will be applied to the ID once IDP_CFG is
set to 1 thus changing the ID from bank A
to bank B. 0 = bank A 1 = bank B
READY
IDPA_INTG
67
0
15
RW
The terms of an a + b/c desired divid-
er setting must be processsed into ID-
PA_INTG, IDPA_RES, and IDPA_DEN
register terms.intg = floor(((a*c+b)*128/c)
- 512).
READY
IDPA_RES
69
0
15
RW
res = mod(b*128, c)
READY
IDPA_DEN
6B
0
15
RW
den = c
READY
P_VAL
75
0
5
RW
Chooses the PLL prescalar divide ratio.
READY
USYS_START
B8
0
8
RW
User defined application startup behavior.
Flags for SW what to do at the startup,
for example moving to ACTIVE on its own
upon startup or waiting in READY state
for a command. Used only upon startup,
Initialized from NVM.
READY
PLL_MODE
BE
2
4
RW
Sets PLL BW. See table 5
READY
XOSC_CINT_ENA
BF
7
1
RW
Enabled integrated capacitance on XA
and XB.
READY
XOSC_CTRIM_XA
C0
0
6
RW
Load capacitance trim on XA.
READY
XOSC_CTRIM_XB
C1
0
6
RW
Load capacitance trim on XB.
READY
OUT0_1_MODE
7A
0
4
RW
Software interpreted driver configura-
tion.See table 3
READY
OUT0_1_DIV
7B
0
6
RW
Driver divider ratio. 0 = disabled 1-63 =
divide value
READY
OUT0_1_SKEW
7C
0
3
RW
Skew control. Programmed as an un-
signed integer. Can add delay of 35 ps/
step up to 280 ps.
READY
OUT0_1_STOP_HIGHZ
7D
0
1
RW
Driver output state when stopped. 0 = low-
z 1 = high-z
READY
OUT0_1_CMOS_INV
7D
4
2
RW
Sets the polarity of the two outputs. 0 = no
inversion 1 = OUT1 inverted
READY
OUT0_1_CMOS_SLEW
7E
0
2
RW
Controls CMOS slew rate from fast to
slow. 00 = fastest 01 = slow 10 = Slower
11 = slowest
READY
OUT0_1_CMOS_STR
7E
2
1
RW
CMOS output impedance control. 0 = 50
Ohm 1 = 25 Ohm
READY
OUT2_3_MODE
7F
0
4
RW
Software interpreted driver configura-
tion.See table 3
READY
Si5357 Reference Manual • Register Map
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
30
Rev. 0.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 26, 2021