24
Installation Manual
5.2.1 Installation Site Instructions
Installing the unit in the following places maycause malfunction. If it is unavoidable, please consult the local dealer:
1.The place with strong heat sources,vapors,flammable or explosive gas,or volatile objects spread in the air.
2.The place with high-frequency devices (such as welding machine,medical equipment).
3.The place near coast area.
4.The place with oil or fumes in the air.
5.The place with sulfureted gas.
6.Other places with special circumstances.
7.The appliance shall not be installed in the laundry.
1. There should be noobstruction near air inlet and air outlet.
2. Select a location where the condensation water can be dispersed easily and won't affect other people.
3. Select a location which is convenient to connect the outdoor unit and near the power socket.
4. Select a location which is out of reach for children.
5. The location should be ableto withstand the weight of indoor unit and won't increase noise and vibration.
6. The appliance must be installed 2.5m above fioor.
7. Don't install the indoor unit right above the electric appliance.
8. Please try your best to keep way from fluorescent lamp.
1.Select a location where the noise and out flow air emitted by the outdoor unit will not affect neighborhood.
2.The location should be well ventilated and dry, in which the outdoor unit won't be exposed directly to sunlight or strong wind.
3.The location should be able to withstand the weight of outdoor unit.
4.Make sure that the installation follows the requirement of installation dimension diagram.
5.Select a location which is out of reach for children and far away from animals or plants.If it is unavoidable, please add the
fence for safety purpose.
5.2.2 Installation Site of Indoor Unit
5.2.3 Installation Site of Outdoor Unit
5.2.4 Safety Precautions for Electric Appliances
1. A dedicated power supply circuit should be used in accordance with local electrical safety regulations.
2. Don't drag the power cord with excessive force.
3. The unit should be reliably earthed and connected to an exclusive earth device by the professionals.
4. The air switch must have the functions of magnetic tripping and heat tripping to prevent short circuit and overload.
5. The minimum distance between the unit and combustive surface is 1.5m.
6. The appliance shall be installed in accordance with national wiring regulations.
7. An all-pole disconnection switch with a contact separation of at least 3mm in all poles should be connected in fixed wiring.
Note:
● Make sure the live wire, neutral wire and earth wire in the family power socket are properly connected.
There should be reliable circuit in the diagram.
● Inadequate or incorrect electrical connections may cause electric shock or fire.
5.2.5 Earthing Requirements
1. Air conditioner is type
I
electric appliance. Please ensure that the unit is reliably earthed.
2. The yellow-green wire in air conditioner is the earthing wire which can not be used for other purposes. Improper earthing may
cause electric shock.
3. The earth resistance should accord to the national criterion.
4. The power must have reliable earthing terminal. Please do not connect the earthing wire with the following:
● Water pipe
● Gas pipe
● Contamination pipe
● Other place that professional personnel consider is unreliable
5. The model and rated values of fuses should accord with the silk print on fuse cover or related PCB.