Industrial Power Supplies
Single Output 1500 Watt
TF1500 Family
TF1500 Application Note v1019
Copyright © 2019 SL Power Electronics Corp. All rights reserved.
Page 19
Fig. 47: LOCAL CURRENT PROGRAM (ACI) 115VAC.
CH1: Output Voltage.
CH2: Current Program (ACI).
CH4: Output Load Current (Aout) 1.5KW/62.5A (10A/Div).
Input Voltage: 115VAC.
CH1: Output Voltage.
CH2: Current Program (ACI).
CH4: Output Load Current (Aout) 1.5KW/62.5A (10A/Div).
Input Voltage: 230VAC.
Fig. 48: LOCAL CURRENT PROGRAM (ACI) 230VAC.
TF1500A24K01
TF1500A24K01
Constant Resistance Mode
On the Constant Resistance Mode scope plots, the UUT output is loaded with fixed resistance. It also shows how the load current fol-
lows the ACI signal and that the output voltage follows the load current all the way to when the ACI signal has reached the programable
level for a current limit above the load resistance level being applied to the UUT.
Fig. 49: LOCAL CURRENT PROGRAM (ACI) 115VAC.
CH1: Output Voltage.
CH2: Current Program (ACI).
CH4: Output Load Current (Aout) 1.5KW/62.5A (10A/Div).
Input Voltage: 115VAC.
CH1: Output Voltage.
CH2: Current Program (ACI).
CH4: Output Load Current (Aout) 1.5KW/62.5A (10A/Div).
Input Voltage: 230VAC.
Fig. 50: LOCAL CURRENT PROGRAM (ACI) 230VAC.
TF1500A24K01