Industrial Power Supplies
Single Output 1500 Watt
TF1500 Family
TF1500 Application Note v1019
Copyright © 2019 SL Power Electronics Corp. All rights reserved.
Page 27
Fig. 77: CE Quasi Peak & Average 100% Load. 120V/60Hz Line.
Fig. 78: CE Quasi Peak & Average 100% Load. 240V/60Hz Line.
Conducted Emission
EMI Plots were collected at 10% and 100% loads, 120VAC/60Hz and 240VAC/50Hz. The Curves are Quasi-peak (QP) and Average mea-
surements. The QP and Average value point data is not shown in these plots, but detailed EMI reports are available upon request.
Fig. 79: CE Quasi Peak & Average 100% Load. 120V/60Hz Neutral.
Fig. 80: CE Quasi Peak & Average 100% Load. 240V/60Hz Neutral.