DIAGNOSTIC ERROR CODES

WARNING: 

If an operational problem has occurred, the boiler will

shut off and show an “A”, “E” or “H” in the mode dis-

play, along with an error code in the temperature dis-

play.

Do not attempt performing any service under these

conditions, but do note the mode and temperature dis-

play indication, in case the problem clears itself. An “A”

indication error can be cleared by pressing the reset

button once, which will allow re-try of operation. Do not

repeatedly press the reset button in this case, or if an

“E” or “H” indication error is displayed. Call a trained,

experienced service technician to troubleshoot and cor-

rect the problem. The Jaguar Installation and Operating

Instructions, publication J-40 contain a full trou-

bleshooting section for this. Turn off all electric power

ot the boiler before service.

A. LOCKOUT ERRORS: 

Indicated by an “A” in the mode display. The reset 

button must be pressed to clear the error and retry 

operation. The temperature display shows the error 

code.

B. BLOCKING ERRORS: 

Indicated by an “E” in the mode display. Operation

is automatically restored, once the condition returns

to normal or is fixed. The temperature display

shows the error code. Pressing the “Reset” button

is not required.

C. WARNING ERRORS: 

Indicated by an “H” in the mode display. Operation 

of the space heating mode is not affected, and the 

warning is displayed intermittently. Operation of the 

DHW mode is automatically restored, once the

condition is fixed. The temperature display shows 

the error code. Pressing the “Reset” button is

not required.

ERROR

CODE

INDICATION

01

Ignition Failure - 3 unsuccessful ignition

attempts in a row

02

Flame Failure - 3 losses of flame signal 

during one demand

03

Water High Limit Open

04, 05, 09,
10, 12, 13,
14, 15, 16,

18, 32

Control Failure

19, 20

Flame Detected at Wrong Time

33

Fan Failure - RPM Error

ERROR

CODE

INDICATION

01

Water Outlet Sensor Open

02

Water Inlet Sensor Open

03

Flue Gas Sensor Open

11

Water Outlet Sensor Shorted

12

Water Inlet Sensor Shorted

13

Flue Gas Sensor Shorted

19, 42,
45, 46,

47, 48

Control Failure

20

Flame Detected at Wrong Time

21

Polarity Error

22

Frequency Error

24

Earth Connection Faulty

30

Excess Flue Temperature

31

Low Water Cutoff Error

32

Excess Water Inlet Temperature

51

Reset Button Error

52

Boiler Model Selection Error

ERROR

CODE

INDICATION

04

Domestic Hot Water Tank Sensor Open

14

Domestic Hot Water Tank Sensor Shorted

Summary of Contents for J-390

Page 1: ...nity of this or any other appliance __ WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electrical switch DO NOT use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas suppli er s instructions If you cannot reach your gas supplier call the fire department __ Installation and service must be performed by a qualified ins...

Page 2: ...s boiler if any part has been underwater Immediately call a qualified service technician to inspect the boiler and to replace any part of the control system and any gas control which has been underwater WARNING Should overheating occur or the gas supply fail to shut off DO NOT turn off or disconnect the electric supply to the circulator pump Instead shut off the gas supply at a location EXTERNAL t...

Page 3: ... Non direct vent installation is shown on Figures 4 5 and 6 1 VENTING AND AIR INTAKE SYSTEM REGULAR INSPECTION Inspect the system regularly for condensation corrosion sagging and or physical damage A qualified professional should service the boiler annually and include such an inspection at that time The homeowner should look over the system monthly for damage water stains any signs of rust other ...

Page 4: ...Jaguar Model J 390 4 AIR INTAKE DO NOT BLOCK 4 DIA VENT PIPE VENT TERMINATION OUTSIDE WALL Figure 4 Non direct vent sidewall venting 102mm 4 DIA VENT PIPE ...

Page 5: ...RMINATION 4 DIA VENT PIPE AIR INTAKE DO NOT BLOCK Figure 6 Non direct vent utilizing an existing chimney as a chase VENT TERMINATION CHIMNEY TOP PLATE 4 DIA VENT PIPE 4 DIA VENT PIPE AIR INTAKE DO NOT BLOCK UNUSED CHIMNEY 102mm 4 DIA VENT PIPE 102mm 4 DIA VENT PIPE 102mm 4 DIA VENT PIPE ...

Page 6: ...ure is normally indicated on the tempera ture display See Figure 1 for location and Figure 9 for digits illustration For most installations it should indicate about 83 to 103 kPa 12 to 15 psi pressure when temperature is about 21 to 38 C 70 to 100 F and from 103 to 172 kPa 15 psi to 25 psi when tem perature is up to 91 C 195 F FOR YOUR SYSTEM there is one correct pressure for each temperature ASK ...

Page 7: ...uilding Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to turn the gas supply shut off valve Never use tools If the supply shut off will not turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or ex...

Page 8: ... C 90 to 185 F 2 While d is blinking boiler supply water tempera ture for DHW may be set to desired temperature The setting range is between 40 to 85 C 104 to 185 F 3 While t is blinking DHW tank temperature may be set to desired temperature if tank is equipped with sensor The setting range is between 40 to 85 C 104 to 185 F 4 View actual following temperatures on Temperature Display Press Select ...

Page 9: ...pressed to resume normal operation Error Condition Temperature display indicates the error code Warning Condition Temperature display indicates the error code Jaguar Boiler Display Board Boiler Operation Status Note Blinking dot on Mode Display indicates active heating control burner off Steady dot indicates burner is on Error must be corrected to resume boiler operation Pressing the Reset button ...

Page 10: ...Settable from 40 to 71 C 104 F to 160 F steps of 0 55 C 1 F The default valve is 60 C 140 F Press Enter button to store see note 3 Temperature display shows actual supply water temperature Temperature display shows actual return water temperature Temperature display shows actual DHW tank temperature if the water tank is equipped with sensor Temperature display shows actual flue gas temperature Tem...

Page 11: ...d once the condition returns to normal or is fixed The temperature display shows the error code Pressing the Reset button is not required C WARNING ERRORS Indicated by an H in the mode display Operation of the space heating mode is not affected and the warning is displayed intermittently Operation of the DHW mode is automatically restored once the condition is fixed The temperature display shows t...

Page 12: ... FIN LTD LTEE 6450 Northam Drive Mississauga Ontario L4V 1H9 Phone 905 677 8400 FAX 905 677 1829 Order Desk Fax 905 677 9015 www slantfin ca E mail orderdesk slantfin ca info slantfin ca Slant Fin Corp 2008 ...

Reviews: